The use of QSD (q-sequence deconvolution) to recover superposed, transient evoked-responses.
نویسندگان
چکیده
OBJECTIVE We describe q-sequence deconvolution (QSD), a new data acquisition/analysis method for evoked-responses that solves the problem of waveform distortion at high stimulus repetition-rates, due to response overlap. QSD can increase the sensitivity of clinically useful evoked-responses because it is well known that high stimulus repetition-rates are better for detecting pathophysiology. METHODS QSD is applicable to a variety of experimental conditions. Because some QSD-parameters must be chosen by the experimenter, the underlying principles and assumptions of the method are described in detail. The theoretical and mathematical bases of the QSD method are also described, including some equivalent computational formulations. RESULTS QSD was applied to recordings of the human auditory brainstem response (ABR) at stimulus repetition-rates that overlapped the responses. The transient ABR was recovered at all rates tested (highest 160/s), and showed systematic changes with stimulus repetition-rate within a single subject. CONCLUSIONS QSD offers a new method of recovering brain evoked-response activity having a duration longer than the time between stimuli. SIGNIFICANCE The use of this new technique for analysis of evoked responses will permit examination of brain activation patterns across a broad range of stimulus repetition-rates, some never before studied. Such studies will improve the sensitivity of evoked-responses for the detection of brain pathophysiology. New measures of brain activity may be discovered using QSD. The method also permits the recovery of the transient brain waveforms that overlap to form 'steady-state' waveforms. An additional benefit of the QSD method is that repetition-rate can be isolated as a variable, independent of other stimulus characteristics, even if the response is a nonlinear function of rate.
منابع مشابه
Improved Transient Response Estimations in Predicting 40 Hz Auditory Steady-State Response Using Deconvolution Methods
The auditory steady-state response (ASSR) is one of the main approaches in clinic for health screening and frequency-specific hearing assessment. However, its generation mechanism is still of much controversy. In the present study, the linear superposition hypothesis for the generation of ASSRs was investigated by comparing the relationships between the classical 40 Hz ASSR and three synthetic ...
متن کاملEvaluation of Distortion and Transient Evoked Otoacoustic Emission in Tinnitus Patients with Normal Hearing
Introduction: Tinnitus is a perception of sound without external source. The exact etiology of tinnitus is not fully understood, although some researchers believe that the condition usually starts in the cochlea. The aim of this study was to determine the potential contribution of outer hair cell dysfunction to chronic tinnitus, by application of Distortion-Product Evoked Otoacoustic Emission (...
متن کاملThe Relationship between the Behavioral Hearing Thresholds and Maximum Bilirubin Levels at Birth in Children with a History of Neonatal Hyperbilirubinemia
Introduction: Neonatal hyperbilirubinemia is one of the most important factors affecting the auditory system and can cause sensorineural hearing loss. This study investigated the relationship between behavioral hearing thresholds in children with a history of jaundice and the maximum level of bilirubin concentration in the blood. Materials and Methods: This study was performed on 18 children...
متن کاملNew metric for optimizing Continuous Loop Averaging Deconvolution (CLAD) sequences under the 1/f noise model
Continuous loop averaging deconvolution (CLAD) is one of the proven methods for recovering transient auditory evoked potentials (AEPs) in rapid stimulation paradigms, which requires an elaborated stimulus sequence design to attenuate impacts from noise in data. The present study aimed to develop a new metric in gauging a CLAD sequence in terms of noise gain factor (NGF), which has been proposed...
متن کاملNoise Attenuation Estimation for Maximum Length Sequences in Deconvolution Process of Auditory Evoked Potentials
The use of maximum length sequence (m-sequence) has been found beneficial for recovering both linear and nonlinear components at rapid stimulation. Since m-sequence is fully characterized by a primitive polynomial of different orders, the selection of polynomial order can be problematic in practice. Usually, the m-sequence is repetitively delivered in a looped fashion. Ensemble averaging is car...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical neurophysiology : official journal of the International Federation of Clinical Neurophysiology
دوره 115 12 شماره
صفحات -
تاریخ انتشار 2004