A new directly moulded patellar-tendon-bearing socket.

نویسندگان

  • D A Boot
  • N J Young
چکیده

Silicone rubbers and casting tapes individually have previously been used in the manufacture of sockets (Swanson, 1972; Sweitzer, 1973; Ruder, 1977; Graves, 1980; Aqualite, 1982). The authors believe that the present combination of these materials to manufacture a directly moulded socket with a complete silicone rubber lining of variable thickness has not previously been described. The new socket, after addition of the modular components, allows fitting of an aligned below-knee prosthesis within three hours. The socket (Fig. 1.) is made directly on the below-knee stump, can be completed with experience in an hour and does not require the use of specialized equipment. The socket consists of an outer supportive Scotchflex layer inside which is a lining of soft smooth biocompatible silicone rubber of deliberately variable thickness to allow pressure tolerant areas to accept more load and pressure sensitive areas to accept less load (Fig.2). The thicker areas of silicone are produced by applying carefully cut Plastazote pads to the pressure sensitive areas. The thickness and extent of the pads is individually assessed according to the estimated sensitivity of the particular area (Fig. 3). The Scotchflex socket is then manufactured directly on the below-knee stump with these pads applied. The pads are then removed prior to insertion of a semi-liquid silicone rubber. Thus, when the socket with the liquid silicone rubber is re-applied to the stump, the space produced by the pads is filled by the rubber which then sets at room temperature. In this way a layer of variable thickness is produced.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interface pressure profile analysis for patellar tendon-bearing socket and hydrostatic socket.

Conventionally, patellar tendon-bearing (PTB) sockets, which need high dexterity of prosthetist, are widely used. Lack of chartered and experienced prosthetist has often led to painful experience of wearing prosthesis and this will in turn deter the patients to wear the prosthesis, which will further aggravate stump shrinkage. Thus, the hydrostatic socket which demands relatively lower level of...

متن کامل

Development of Refined Fitting Procedures for Lower-extremity Prosthese

With the development of the patellar-tendon-bearing prosthesis by the University of California at Berkeley, many new advantages in simplicity, comfort, and function were available to the below-knee amputee. However, there still exists the problem of concentrated pressures over small areas of the stump. The original design of the patellar-tendonbearing prosthesis was intended to distribute the l...

متن کامل

The evolution of functional bracing of fractures.

©2006 British Editorial Society of Bone and Joint Surgery doi:10.1302/0301-620X.88B2. 16381 $2.00 J Bone Joint Surg [Br] 2006;88-B:141-8. Functional fracture bracing, described in 1967, 1 was inspired by the patellar-tendonbearing prosthesis which had recently been developed for below-knee amputees. This prosthesis had eliminated the traditional thigh corset and allowed the transfer of weight-b...

متن کامل

Comparative study between patellar-tendon-bearing and pressure cast prosthetic sockets.

This study compared the pressure distribution at the residual limb and socket interface in amputees wearing a pressure cast (PCast) socket system with amputees wearing the patellar-tendon-bearing (PTB) socket. The PCast system requires the subject to place his or her residual limb in a pressure chamber. Pressure is applied to the residual limb while the subject adopts a normal standing position...

متن کامل

Analysis of a below-knee patellar tendon-bearing prosthesis: a finite element study.

In this study, a finite element (FE) model of a below-knee prosthesis of patellar tendon-bearing (PTB) design, and several altered variations of the model have been constructed. A load of approximately 1.5 times normal body weight (984 N) was applied at the heel of the model to simulate heelstrike conditions. The "base" model was then analyzed and revised iteratively until a model which provide...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prosthetics and orthotics international

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 1985