Evaluation of Soft Tissue Sarcoma Tumors Electrical Conductivity Anisotropy Using Diffusion Tensor Imaging for Numerical Modeling on Electroporation
نویسندگان
چکیده
INTRODUCTION There is many ways to assessing the electrical conductivity anisotropy of a tumor. Applying the values of tissue electrical conductivity anisotropy is crucial in numerical modeling of the electric and thermal field distribution in electroporation treatments. This study aims to calculate the tissues electrical conductivity anisotropy in patients with sarcoma tumors using diffusion tensor imaging technique. MATERIALS AND METHOD A total of 3 subjects were involved in this study. All of patients had clinically apparent sarcoma tumors at the extremities. The T1, T2 and DTI images were performed using a 3-Tesla multi-coil, multi-channel MRI system. The fractional anisotropy (FA) maps were performed using the FSL (FMRI software library) software regarding the DTI images. The 3D matrix of the FA maps of each area (tumor, normal soft tissue and bone/s) was reconstructed and the anisotropy matrix was calculated regarding to the FA values. RESULT The mean FA values in direction of main axis in sarcoma tumors were ranged between 0.475-0.690. With assumption of isotropy of the electrical conductivity, the FA value of electrical conductivity at each X, Y and Z coordinate axes would be equal to 0.577. The gathered results showed that there is a mean error band of 20% in electrical conductivity, if the electrical conductivity anisotropy not concluded at the calculations. The comparison of FA values showed that there is a significant statistical difference between the mean FA value of tumor and normal soft tissues (P<0.05). CONCLUSION DTI is a feasible technique for the assessment of electrical conductivity anisotropy of tissues. It is crucial to quantify the electrical conductivity anisotropy data of tissues for numerical modeling of electroporation treatments.
منابع مشابه
Evaluation of Soft Tissue Sarcoma Tumors Electrical Conductivity Anisotropy Using Diffusion Tensor Imaging for Numerical Modeling on Electroporation
Introduction: There is many ways to assessing the electrical conductivity anisotropyof a tumor. Applying the values of tissue electrical conductivity anisotropyis crucial in numerical modeling of the electric and thermal field distribution in electroporationtreatments. This study aims to calculate the tissues electrical conductivityanisotropy in patients with sarcoma tumors using diffusion tens...
متن کاملEvaluation of Diffusion Anisotropy and Diffusion Shape in Grading of Glial Tumors
Background: The most common primary tumors of brain are gliomas. Grading of tumor is vital for designing proper treatment plans. The gold standard choice to determine the grade of glial tumor is biopsy which is an invasive method.Objective: In this study, we try to investigate the role of fractional anisotropy (diffusion anisotropy) and linear anisotropy ...
متن کاملAssessing how electroporation affects the effective conductivity tensor of biological tissues
We report calculations of the anisotropy ratio of the electrical conductivity of a simple model of a loose connective biological tissue described as a random assembly of multiscale undeformable core-shell and controlled polydisperse spherical structures. One can estimate a 10% increase in the anisotropy ratio due to the application of electric field (duration 100 lm) above the electroporation t...
متن کاملApplication potential of susceptibility-weighted imaging (SWI), diffusion weighted imaging (DWI) and diffusion tensor imaging (DTI) in the diagnosis of soft tissue tumors
Objective: The prime aim of the present study was to analyse the application value of 3.0 T Susceptibility Weighted Imaging (SWI), Diffusion Weighted Imaging (DWI) and Diffusion Tensor Imaging (DTI) sequence in the diagnosis of benign as well as malignant soft tissue tumors. Methods: 30 cases of benign soft tissue tumor and 30 cases of malignant soft tissue tumor (diagnosed pathologically) were...
متن کاملDetermining anisotropic conductivity using diffusion tensor imaging data in magneto-acoustic tomography with magnetic induction
In this paper we present a mathematical and numerical framework for a procedure of imaging anisotropic electrical conductivity tensor by integrating magneto-acoutic tomography with data acquired from diffusion tensor imaging. Magneto-acoustic Tomography with Magnetic Induction (MAT-MI) is a hybrid, non-invasive medical imaging technique to produce conductivity images with improved spatial resol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2016