Active Frequency Drift Method for Islanding Detection Applied to Micro-inverter with Uncontrollable Reactive Power
نویسندگان
چکیده
This paper proposes active frequency drift (AFD) as an anti-islanding method applied to micro-inverters with uncontrollable reactive power. When using ordinary inverter topologies, such as full bridge inverters in photovoltaic systems, the islanding phenomenon can be detected with reactive power-based methods, such as reactive power variation. However, when the inverter topology cannot control the reactive power, conventional anti-islanding methods with reactive power cannot be utilized. In this work, the topology used in this paper cannot control the reactive power. Thus, an anti-islanding method that can be used in topologies that cannot control the reactive power is proposed. The conventional anti-islanding method of the topology that cannot control reactive power is introduced and analyzed. Unlike the conventional AFD method, the proposed method extends a zero current interval every predetermined cycle. The proposed method offers certain advantages over conventional AFD methods, such as total harmonic distortion. The proposed method is validated through simulation and experiment.
منابع مشابه
A Proposed Hybrid Method For Islanding Detection
In this paper Islanding detection methods for distributed resources are reviewed. The mainly used islanding detection techniques may be classified as active and passive techniques. Passive techniques don’t perturb the system but they have larger nondetection zones, whereas active techniques have smaller nondetection zones but they perturb the system. In this paper a new hybrid method is propose...
متن کاملMicrogrid Islanding Detection Method based on Frequency - Reactive Power Feedback
Islanding detection is one of the essential features for photovoltaic grid-connected systems; detection performance is directly related to safe operation of the equipment. Summarize existing islanding detection, then an active method based on frequency – reactive power feedback islanding detection is proposed. Once an islanding condition occurs, the method introducing a load frequency reactive ...
متن کاملA Novel Passive Method for Islanding Detection in Microgrids
Integration of distributed generations (DGs) in power grids is expected to play an essential role in the infrastructure and market of electrical power systems. Microgrids are small energy systems, capable of balancing captive supply and requesting resources to retain stable service within a specific boundary. Microgrids can operate in grid-connected or islanding modes. Effective islanding detec...
متن کاملA reference current perturbation method for islanding detection of a multi-inverter system
An active islanding detection method without destabilizing the system gives the advantage of accurate decision and the capability to keep the micro-grid energized while islanding occurs. Harmonic and perturbation current injection are such active methods, but none in the literature has discussed about islanding detection in multi-inverter systems. This paper proposes an active islanding detecti...
متن کاملInverter based distributed generator islanding detection method using U/O voltage relay
Islanded operation of distributed generators is a problem that can take place when they are connected to a distribution system. In this paper an islanding detection method is presented for inverter based distributed generation (DG) using under/over voltage relay. The method is an adaptive one and is based on the change of DG active power reference (Pref) in inverter control interface. The activ...
متن کامل