Venous intravasation: a potential pitfall of confirmatory hysterosalpingogram following essure hysteroscopic sterilization.

نویسندگان

  • Michael C Chang
  • John J Shim
چکیده

Indications for hysterosalpingography (HSG) include evaluation of infertility, spontaneous abortions, postoperative evaluation of tubal ligation, pre-myomectomy evaluation, and more recently, evaluation of tubal occlusion after placement of the Essure Permanent Birth Control System. Here we report a case of venous intravasation during a routine post-Essure HSG, a phenomenon in which contrast transits from the uterine cavity, through the myometrium, and directly into draining pelvic veins. Venous intravasation is a potential pitfall in interpretation of HSGs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Duration of Endometrial Preparation and Essure Hysteroscopic Sterilization Placement Success

Study Design: An institutional review board (IRB) approved retrospective cohort study of all women who underwent hysteroscopic sterilization from August 2003 to April 2010 in an urban academic center in Chicago, Illinois was performed. Exclusion criteria included insufficient or incomplete data. Variables including Essure placement success, type and duration of endometrial preparation, demograp...

متن کامل

Discordant relationship between Essure microinsert position and tubal occlusion.

Hysteroscopic sterilisation with Essure requires confirmation of tubal occlusion by hysterosalpingogram or microinsert position by transvaginal sonography 3 months after placement before women can rely on the method for pregnancy prevention. A 39-year-old woman underwent hysteroscopic sterilisation via Essure, with successful bilateral tubal occlusion documented on hysterosalpingogram. She had ...

متن کامل

Reproducibility of the interpretation of pelvic x-ray 3 months after hysteroscopic sterilization with Essure.

OBJECTIVE To estimate the diagnostic accuracy and the interobserver reproducibility of pelvic x-rays in the diagnosis of successful bilateral sterilization with Essure after a 3-month follow-up period. DESIGN Interobserver study. SETTING Outpatient department of obstetrics and gynecology in a Dutch teaching hospital. PATIENT(S) Patients with successful bilateral Essure placement. INTERV...

متن کامل

Essure hysteroscopic tubal occlusion device for the treatment of hydrosalpinx prior to in vitro fertilization-embryo transfer in patients with a contraindication for laparoscopy.

OBJECTIVE To investigate the success rate of proximal tubal occlusion with Essure devices in subfertile women with hydrosalpinges, and to observe the results of subsequent treatment with IVF. DESIGN Prospective, single-arm, clinical study. SETTING University hospital and teaching hospital. PATIENT(S) Ten women with uni- or bilateral hydrosalpinges prior to IVF. In all patients laparoscopy...

متن کامل

Analysis of adverse events with Essure hysteroscopic sterilization reported to the Manufacturer and User Facility Device Experience database.

STUDY OBJECTIVE The Manufacturer and User Facility Device Experience database may be useful for clinicians using a Food and Drug Administration-approved medical device to identify the occurrence of adverse events and complications. We sought to analyze and investigate reports associated with the Essure hysteroscopic sterilization system (Conceptus Inc., Mountain View, CA) using this database. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiology case reports

دوره 6 9  شماره 

صفحات  -

تاریخ انتشار 2012