The evaluation of CBRN canisters for use by firefighters during overhaul.

نویسندگان

  • Jennifer Currie
  • Delayne Caseman
  • T Renee Anthony
چکیده

Air-purifying respirators (APRs) have been proposed to provide an additional respiratory protection option for structural firefighters involved in overhaul operations and wildland firefighters, where particulate and aldehyde exposures have been documented. Previous studies (Anthony et al., 2007) developed test methods to evaluate APR cartridges and canisters for use in overhaul activities, where initial findings indicated that multi-gas cartridges may not be effective. This study evaluated the performance of three chemical, biological, radiological, and nuclear (CBRN) canisters (MSA, 3M, and Scott) and one multi-gas canister similar in appearance to CBRN canisters but without CBRN certification (3M FR-64040). Challenge concentrations typical of overhaul exposures were generated by combusting common household materials. Twelve tests were conducted, using random canister selection, where challenge air and air filtered by the canisters were tested. All tests examined penetration of CO; NO(2); SO(2); respirable dust; aldehydes, including formaldehyde, acrolein, and glutaraldehyde; and hydrogen cyanide. Six of the tests also investigated naphthalene, benzene, and hydrogen chloride, but challenge concentrations from the simulated overhaul smoke were near the limit of detection (LOD) and were two orders of magnitude below short-term or ceiling concentrations of concern and were eliminated from further study with the combustion materials used in this study. In all tests, an irritant index was computed to evaluate the aggregate penetration of contaminants in the smoke mixture, using 15- and 30-min occupational exposure limits as well as assessing individual penetrations. In all cases, the challenge concentration irritant index exceeded unity, ranging from 2.3 to 21. For all 12 tests, the APR canister reduced the overall irritant index to levels below unity, indicating that these canisters would provide protection for firefighters working in overhaul environments. However, in some tests, levels of carbon monoxide were higher than recommended for persons wearing APRs. Since these canisters do not protect against carbon monoxide, firefighters must still rely on direct reading warning to indicate high CO levels, indicating the need to leave the area if wearing an APR, as these APR canisters would be inappropriate.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Respiratory protection for firefighters--evaluation of CBRN canisters for use during overhaul.

In the United States, there are approximately 366,600 structural fires each year. After visible flames are extinguished, firefighters begin the overhaul stage of firefighting to smother remaining hot spots and initiate investigations. Typically during overhaul significant ambient concentrations of chemical contaminants remain. However, previous research suggests that the use of air purifying re...

متن کامل

Respiratory protection for firefighters--Evaluation of CBRN canisters for use during overhaul II: In mask analyte sampling with integrated dynamic breathing machine.

According to the National Fire Protection Association there were 487,500 structural fires in the U.S. in 2013. After visible flames are extinguished firefighters begin the overhaul stage where remaining hot spots are identified and further extinguished. During overhaul, a significant amount of potentially hazardous chemicals can remain in the ambient environment. Previous research suggests that...

متن کامل

Ultrafine particle exposure during fire suppression--is it an important contributory factor for coronary heart disease in firefighters?

OBJECTIVE Coronary heart disease (CHD) is the primary cause of death among US firefighters during fire suppression. In other populations, exposure to respirable particles, including ultrafine particles, has been widely implicated as a risk factor for CHD. This study is the first to report detailed characterization of respirable particles released by combustion of an automobile and model residen...

متن کامل

Optimal overhaul–replacement policy for a multi-degraded repairable system sold with warranty

In this research, we study an optimal overhaul–replacement policy of a multi-degraded repairable system sold with a free replacement warranty. In the proposed replacement policy, a maintenance action and failure are dependent on a system degradation level and the system age, and hence the replacement model will provide more effective maintenance decisions. Failure of the system is modeled using...

متن کامل

Method development study for APR cartridge evaluation in fire overhaul exposures.

In the US, firefighters do not typically wear respiratory protection during overhaul activities, although fitting multi-gas or chemical, biological, radiological and nuclear cartridges to supplied air respirator facepieces has been proposed to reduce exposures. This work developed a method to evaluate the effectiveness of respirator cartridges in smoke that represents overhaul exposures to resi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Annals of occupational hygiene

دوره 53 5  شماره 

صفحات  -

تاریخ انتشار 2009