Soft Copy Digital Mammography

نویسنده

  • Hak Hee Kim
چکیده

Soft Copy Digital Mammography creen-film mammography (SFM) has been the standard method used for breast cancer screening and making a clinical diagnosis. It is a valuable modality for the detection and differentiation of breast calcifications. The advantages are the high spatital resolution, the convinient display, and inexpensiveness. However, it has some inherent limitations such as its low detective quantum efficiency and the difficulty of post-processing after obtaining an image. Digital mammography (DM) has the potential to overcome the inherent limitations of SFM. DM systems directly qualify x-ray photons and decouple the process of x-ray photon detection from the image display. The digital images can be processed by a computer and displayed in multiple formats. Thus, DM is better than SFM for the detection of mass lesions due to its high contrast resolution. However, one of the main clinical tasks of digital mammography is the detection and characterization of breast calcifications. When comparing SFM to DM, SFM has an advantage over DM because it has higher spatial resolution then DM and the detailed image features may be more obvious. On the other hand, DM has higher contrast resolution with the ability to adjust the contrast of the mammograms through use of image processing. While it is possible to improve visibility of calcifications through increasing the spatial resolution, spatial resolution is not the sole factor influencing the visibility of lesion. Contrast resolution is also important in some instances for diagnosing calcifications and the other small features in the image through manipulating the contrast resolution. Several studies have demonstrated that despite the limited spatial resolution, the visibility of calcifications on DM is not significantly different from that on SFM (1 6). In addition, the pixel sizes in the ranges that are studied do not have a strong effect on the radiologists accuracy for the characterization of calcifications (3). Obenauer et al. reported that the flat-panel DM system was superior to SFM in image quality, detail visibility, image exposure and artifacts (6). They concluded that the better contrast detectability and the ability to do the image processing highly compensated for the limitations in spatial resolution. However, most previous reports have focused on comparing observer performance with using SFM and hard copy digital mammography (HCDM). The diagnostic accuracy of the hardcopy and softcopy interpretation is likely to be comparable if a high-resolution laser printer and a high quality workstation having high spatial and contrast resolution …

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of calcification specificity in digital mammography using soft-copy display versus screen-film mammography.

OBJECTIVE The purpose of this study was to compare specificity in the interpretation of calcifications in soft-copy reviewing of digital mammograms versus hard-copy reviewing of screen-film mammograms. MATERIALS AND METHODS A total of 130 consecutive cases with calcifications (44 malignant and 86 benign) that had been evaluated with needle or surgical biopsy were collected. Both screen-film m...

متن کامل

Epidemiology, Prevention, Screening

Background: Over 90% of mammography machines in Japan have already become digital, however, almost three-fourths of them utilize computed radiography (CR). The majority of them necessitate hard copy diagnosis. Therefore, reliability of soft-copy interpretation of CR mammography is still controversial. The purpose of this study is to assess the usefulness and problems of soft-copy interpretation...

متن کامل

Interpretation of digital mammograms: comparison of speed and accuracy of soft-copy versus printed-film display.

PURPOSE To compare the speed and accuracy of the interpretations of digital mammograms by radiologists by using printed-film versus soft-copy display. MATERIALS AND METHODS After being trained in interpretation of digital mammograms, eight radiologists interpreted 63 digital mammograms, all with old studies for comparison. All studies were interpreted by all readers in soft-copy and printed-f...

متن کامل

The effects of gray scale image processing on digital mammography interpretation performance.

RATIONALE AND OBJECTIVES To determine the effects of three image-processing algorithms on diagnostic accuracy of digital mammography in comparison with conventional screen-film mammography. MATERIALS AND METHODS A total of 201 cases consisting of nonprocessed soft copy versions of the digital mammograms acquired from GE, Fischer, and Trex digital mammography systems (1997-1999) and convention...

متن کامل

Educational software as a tool for teaching & learning of digital mammography*

OBJECTIVE: The present study was aimed at evaluating the performance of residents trained in the reading of conventional and digital mammography images with a specific computational tool. MATERIALS AND METHODS: The training was accomplished in the Laboratory of Medical Images Qualification (QualIM – Laboratório de Qualificação de Imagens Médicas). Residents in radiology performed approximately ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2005