Evaluation of a fully mechanised immunoassay--Enzymun-Test System ES 300--and comparison with in-house methods for 8 analytes.
نویسندگان
چکیده
The following analytes were determined with the automated enzyme immunoassay unit, Enzymun-Test System ES 300, and by routine in-house tests, and the results were compared: thyrotropin, free thyroxine, cortisol, immunoglobulin E, digoxin, digitoxin, insulin and carcinoembryonic antigen. The methods used for comparison included two radioimmunoassays, one with enzyme labelling, two with fluorescence enhanced enzyme reactions and 3 luminescence immunoassays. In most cases, the precision of the ES 300 lay between 2 and 5% in all assays in the concentration ranges of clinical interest. The inter-assay variation was almost identical to the intra-assay precision, which reflects the constancy of reagent quality and machine performance. The correlation between in-house and Enzymun-Test was excellent, even though the slope of the regression line was sometimes far from unity, due to the calibration materials used. ES 300 can be used as a stand alone unit and connected to a host computer. As a "walk-away" machine, it is suitable for laboratories with medium length series. It is a multi-batch analyser capable of taking 12 analytes and a maximal series length of 136 tubes excluding standards and controls.
منابع مشابه
Determination of triiodothyronine in serum by enzyme- and radioimmunoassay: a comparative study.
An evaluation of a heterogeneous enzyme immunoassay for determination of triiodothyronine in serum (Enzymun-Test T3, Boehringer Mannheim) is presented. The enzyme immunoassay was compared with the laboratory routine radioimmunoassay. The precision of both assays was satisfactory at triiodothyronine concentrations between 1.0 and 8.0 nmol/l (coefficients of variation from day to day less than or...
متن کاملPerformance evaluation of automated immunoassays on the Technicon Immuno 1 system.
We performed an immunoassay evaluation for various analytes on a fully automated random-access analyzer, the Technicon Immuno 1 system from Bayer Corp. This system involves latex agglutination, magnetic separation sandwich, and magnetic separation competitive immunoassay configurations. The evaluated analytes were thyrotropin (TSH), triiodothyronine, thyroxine, free thyroxine, follitropin, lutr...
متن کاملQuantitative detection of human immunodeficiency virus (HIV) antigen by the Enzymun-Test: comparison with alternative assays and nucleic acid sequence-based amplification of HIV type 1 RNA.
A new modular automated enzyme immunoassay (EIA) (Enzymun-Test HIV Ag: Boehringer Mannheim) for quantitative human immunodeficiency virus (HIV) antigen detection was evaluated by testing a panel of 1,506 serum samples, including seroconversions, dilution series, follow-up samples from patients under antiretroviral therapy, single serum specimens from HIV-seropositive individuals in different st...
متن کاملOne-point recalibration of heterogeneous enzyme immunoassays with non-linear calibration curves.
We have investigated one-point recalibration of heterogeneous enzyme immunoassays involving nonlinear calibration curves. By using a factor determined from a single standard we updated calibration curves obtained earlier by means of multiple-point determination. The prerequisite for this method is a reproducible working procedure, i.e., as ensured by a fully mechanized system. In our investigat...
متن کاملDesigning and evaluation of Dot-ELISA for diagnosis of Fasciola infection in cattle
Fasciolosis is a disease caused by liver fluck of the genus of fasciola. Diagnosis of fasciolosis has been challenging for a long period due to low sensitivity of the coprological diagnostic method. In this study, an in-house Dot-ELISA method; using excretion–secretory (ES Ag) and Crude (Cr Ag) antigens of fasciola was described for diagnosis of fasciolosis in cattle. For this...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies
دوره 31 3 شماره
صفحات -
تاریخ انتشار 1993