Preclinical radiation dosimetry for the novel SV2A radiotracer [18F]UCB-H

نویسندگان

  • Florian Bretin
  • Geoffrey Warnock
  • Mohamed Ali Bahri
  • Joël Aerts
  • Nathalie Mestdagh
  • Tim Buchanan
  • Anne Valade
  • Frédéric Mievis
  • Fabrice Giacomelli
  • Christian Lemaire
  • André Luxen
  • Eric Salmon
  • Alain Seret
  • Alain Plenevaux
چکیده

BACKGROUND [18F]UCB-H was developed as a novel radiotracer with a high affinity for synaptic vesicle protein 2A, the binding site for the antiepileptic levetiracetam. The objectives of this study were to evaluate the radiation dosimetry of [18F]UCB-H in a preclinical trial and to determine the maximum injectable dose according to guidelines for human biomedical research. The radiation dosimetry was derived by organ harvesting and dynamic micro positron emission tomography (PET) imaging in mice, and the results of both methods were compared. METHODS Twenty-four male C57BL-6 mice were injected with 6.96 ± 0.81 MBq of [18F]UCB-H, and the biodistribution was determined by organ harvesting at 2, 5, 10, 30, 60, and 120 min (n = 4 for each time point). Dynamic microPET imaging was performed on five male C57BL-6 mice after the injection of 9.19 ± 3.40 MBq of [18F]UCB-H. A theoretical dynamic bladder model was applied to simulate urinary excretion. Human radiation dose estimates were derived from animal data using the International Commission on Radiological Protection 103 tissue weighting factors. RESULTS Based on organ harvesting, the urinary bladder wall, liver and brain received the highest radiation dose with a resulting effective dose of 1.88E-02 mSv/MBq. Based on dynamic imaging an effective dose of 1.86E-02 mSv/MBq was calculated, with the urinary bladder wall and liver (brain was not in the imaging field of view) receiving the highest radiation. CONCLUSIONS This first preclinical dosimetry study of [18F]UCB-H showed that the tracer meets the standard criteria for radiation exposure in clinical studies. The dose-limiting organ based on US Food and Drug Administration (FDA) and European guidelines was the urinary bladder wall for FDA and the effective dose for Europe with a maximum injectable single dose of approximately 325 MBq was calculated. Although microPET imaging showed significant deviations from organ harvesting, the Pearson's correlation coefficient between radiation dosimetry derived by either method was 0.9666.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the Specificity of [18f]ucb-h for the Isoform Sv2a, Compared with Sv2b and Sv2c

These results allow us to conclude that [18F]UCB-H is a suitable radiotracer for the imaging of the isoform SV2A in vivo. Forty male Sprague-Dawley were divided in two experiments SV2A is a SV2 isoform protein involved in the synaptic vesicle trafficking and in brain process like the epilepsy (1, 2). [18F]UCB-H was developed like a tool to study the role of this isoform with neuroimaging techni...

متن کامل

Evaluation of 18F-UCB-H as a novel PET tracer for synaptic vesicle protein 2A in the brain.

UNLABELLED Synaptic vesicle protein 2 isoforms are critical for proper nervous system function and are involved in vesicle trafficking. The synaptic vesicle protein 2A (SV2A) isoform has been identified as the binding site of the antiepileptic levetiracetam (LEV), making it an interesting therapeutic target for epilepsy. (18)F-UCB-H is a novel PET imaging agent with a nanomolar affinity for hum...

متن کامل

Radiation dosimetry of the α4β2 nicotinic receptor ligand (+)-[18F]flubatine, comparing preclinical PET/MRI and PET/CT to first-in-human PET/CT results

BACKGROUND Both enantiomers of [18F]flubatine are new radioligands for neuroimaging of α4β2 nicotinic acetylcholine receptors with positron emission tomography (PET) exhibiting promising pharmacokinetics which makes them attractive for different clinical questions. In a previous preclinical study, the main advantage of (+)-[18F]flubatine compared to (-)-[18F]flubatine was its higher binding aff...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

Rabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial

Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal mod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2013