Impact of implantable transvenous device lead location on severity of tricuspid regurgitation.

نویسندگان

  • Karima Addetia
  • Francesco Maffessanti
  • Anuj Mediratta
  • Megan Yamat
  • Lynn Weinert
  • Joshua D Moss
  • Hemal M Nayak
  • Martin C Burke
  • Amit R Patel
  • Eric Kruse
  • Valluvan Jeevanandam
  • Victor Mor-Avi
  • Roberto M Lang
چکیده

BACKGROUND Implantable device leads can cause tricuspid regurgitation (TR) when they interfere with leaflet motion. The aim of this study was to determine whether lead-leaflet interference is associated with TR severity, independent of other causative factors of functional TR. METHODS A total of 100 patients who underwent transthoracic two-dimensional and three-dimensional (3D) echocardiography of the tricuspid valve before and after lead placement were studied. Lead position was classified on 3D echocardiography as leaflet-interfering or noninterfering. TR severity was estimated by vena contracta (VC) width. Logistic regression analysis was used to identify factors associated with postdevice TR, including predevice VC width, right ventricular end-diastolic and end-systolic areas, fractional area change, right atrial size, tricuspid annular diameter, TR gradient, device lead age, and presence or absence of lead interference. Odds ratios were used to describe the association with moderate (VC width ≥ 0.5 cm) or severe (VC width ≥ 0.7 cm) TR, separately, using bivariate and stepwise multivariate logistic regression analysis. RESULTS Forty-five of 100 patients showed device lead tricuspid valve leaflet interference. The septal leaflet was the most commonly affected (23 patients). On bivariate analysis, preimplantation VC width, right atrial size, tricuspid annular diameter, and lead-leaflet interference were significantly associated with postdevice TR. On multivariate analysis, preimplantation VC width and the presence of an interfering lead were independently associated with postdevice TR. Furthermore, the presence of an interfering lead was the only factor associated with TR worsening, increasing the likelihood of developing moderate or severe TR by 15- and 11-fold, respectively. CONCLUSION Lead-leaflet interference as seen on 3D echocardiography is associated with TR after device lead placement, suggesting that 3D echocardiography should be used to assess for lead interference in patients with significant TR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D echocardiographic location of implantable device leads and mechanism of associated tricuspid regurgitation.

OBJECTIVES This study sought to: 1) determine the feasibility of using 3-dimensional transthoracic echocardiography (3D TTE) in patients with implantable cardiac resynchronization devices, pacemakers, and defibrillators to visualize the device leads in the right heart and their position relative to the tricuspid valve leaflets; 2) determine the prevalence of different lead positions; and 3) stu...

متن کامل

Bioprosthetic tricuspid valve regurgitation associated with pacemaker or defibrillator lead implantation.

OBJECTIVES The goal of this study was to determine the impact of transvenous pacemaker and defibrillator leads on the incidence of bioprosthetic tricuspid valve (BTV) regurgitation compared with BTV patients without a transvalvular lead. BACKGROUND Although concern has been raised regarding the potential deleterious effect of permanent transvenous device leads on BTV function, little is known...

متن کامل

Transjugular lead fragment extraction to improve tricuspid regurgitation

Introduction A 28-year-old-man with a history of human immunodeficiency virus (HIV), end-stage renal disease requiring hemodialysis, and HIV-related cardiomyopathy with a severely reduced left ventricular ejection fraction (LVEF) and severe tricuspid regurgitation (TR) per a transthoracic echocardiogram (TTE) underwent implantation of a singlechamber implantable cardioverter-defibrillator (ICD)...

متن کامل

3D imaging of device leads: "taking the lead with 3D".

Pacemaker lead–associated tricuspid regurgitation (TR) has been anecdotally described for many years, but investigation has been limited to a small number of observational studies (1). Overall, it seems that worsening of TR is common after transvenous lead placement (2). Perhaps the lack of formal research in this area has stemmed from our previous inability to adequately confirm that device le...

متن کامل

Permanent cardiac pacing and its influence on tricuspid valve function.

Implantation of transvenous devices is a widespread procedure in clinical cardiology. It is well known that the presence of the electrodes in the cardiovascular system can induce fibrosis or fibrous adhesions between them and cause tricuspid regurgitation. Moreover there are suggestions that the placement of the electrode in the tricuspid orifice may also play a role in the development of tricu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography

دوره 27 11  شماره 

صفحات  -

تاریخ انتشار 2014