Optimization of Proton CT Detector System and Image Reconstruction Algorithm for On-Line Proton Therapy

نویسندگان

  • Chae Young Lee
  • Hankyeol Song
  • Chan Woo Park
  • Yong Hyun Chung
  • Jin Sung Kim
  • Justin C Park
چکیده

The purposes of this study were to optimize a proton computed tomography system (pCT) for proton range verification and to confirm the pCT image reconstruction algorithm based on projection images generated with optimized parameters. For this purpose, we developed a new pCT scanner using the Geometry and Tracking (GEANT) 4.9.6 simulation toolkit. GEANT4 simulations were performed to optimize the geometric parameters representing the detector thickness and the distance between the detectors for pCT. The system consisted of four silicon strip detectors for particle tracking and a calorimeter to measure the residual energies of the individual protons. The optimized pCT system design was then adjusted to ensure that the solution to a CS-based convex optimization problem would converge to yield the desired pCT images after a reasonable number of iterative corrections. In particular, we used a total variation-based formulation that has been useful in exploiting prior knowledge about the minimal variations of proton attenuation characteristics in the human body. Examinations performed using our CS algorithm showed that high-quality pCT images could be reconstructed using sets of 72 projections within 20 iterations and without any streaks or noise, which can be caused by under-sampling and proton starvation. Moreover, the images yielded by this CS algorithm were found to be of higher quality than those obtained using other reconstruction algorithms. The optimized pCT scanner system demonstrated the potential to perform high-quality pCT during on-line image-guided proton therapy, without increasing the imaging dose, by applying our CS based proton CT reconstruction algorithm. Further, we make our optimized detector system and CS-based proton CT reconstruction algorithm potentially useful in on-line proton therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

A new model for Spread Out Bragg Peak in proton therapy of uveal melanoma

In this research, in order to improve our calculations in treatment planning for proton radiotherapy of ocular melanoma, we improved our human eye phantom planning system in GEANT4 toolkit. Different analytical models have investigated the creating of Spread Out Bragg Peak (SOBP) in the tumor area. Bortfeld’s model is one of the most important analytical methods. Using convolution method, a new...

متن کامل

A Highly Accelerated Parallel Multi-GPU based Reconstruction Algorithm for Generating Accurate Relative Stopping Powers

Proton Computed Tomography (pCT) is a growing imaging technology in proton therapy planning. By addressing the range uncertainty problem, pCT images suggest more accurate treatment plans than X-ray CT images [1]. The pCT collaboration has developed a proton CT scanner including a silicon-based tracking system and a multi-stage scintillating energy detector for measuring the water equivalent pat...

متن کامل

Block-Iterative and String-Averaging Projection Algorithms in Proton Computed Tomography Image Reconstruction

Proton computed tomography (pCT) is an imaging modality that is based on tracking individual protons as they traverse the object to be imaged. Proton-by-proton tracking is necessary due to the effects of multiple Coulomb scattering (MCS), a process that deviates the proton path from a striaght line. If optimal spatial resolution is to be achieved, the path of each proton must be predicted with ...

متن کامل

Extraction and 3D Segmentation of Tumors-Based Unsupervised Clustering Techniques in Medical Images

Introduction The diagnosis and separation of cancerous tumors in medical images require accuracy, experience, and time, and it has always posed itself as a major challenge to the radiologists and physicians. Materials and Methods We Received 290 medical images composed of 120 mammographic images, LJPEG format, scanned in gray-scale with 50 microns size, 110 MRI images including of T1-Wighted, T...