Transcatheter occlusion of patent ductus arteriosus with adjustable buttoned device. Initial clinical experience.

نویسندگان

  • P S Rao
  • E B Sideris
  • J Haddad
  • C Rey
  • G Hausdorf
  • A D Wilson
  • P A Smith
  • P S Chopra
چکیده

BACKGROUND Several devices are available for transcatheter occlusion of patent ductus arteriosus. Most of these devices either require complicated intracardiac maneuvering, have not been tried in humans, or need a large-sized sheath for implantation of the device. METHODS AND RESULTS During a 26-month period ending November 1992, 14 patients underwent transcatheter closure of patent ductus arteriosus with an adjustable buttoned device delivered via a 7F sheath under an institutional review board-approved custom-made device protocol. The children were 15 months to 8 years of age with weight range of 7.2 to 19 kg. The patent ductus arteriosus measured from 2 to 7.5 mm (median, 3 mm) at the narrowest diameter and was conical, short, or tubular. They were occluded with devices measuring 15 to 20 mm. The ratio of pulmonary to systemic flow decreased (P < .01) from 1.9 +/- 0.6 (mean +/- SD; range, 1.3 to 3.2) to 1.05 +/- 0.1 (1 to 1.3). Continuous murmur of patent ductus arteriosus disappeared in all except 1 patient. Small residual shunts were detected by color Doppler studies in 4 of 14 patients (29%). All patients were followed for 1 to 24 months (mean, 6 +/- 7 months). The device was intact in all patients, and no breakage of the wires was noted. No shunts were seen in 12 of 14 patients (86%), and minute residual shunts were seen in 2 children. No major complications were encountered. CONCLUSIONS It is concluded that transcatheter closure of patent ductus arteriosus with the adjustable buttoned device is feasible and effective and can be accomplished via small 7F sheaths; a 7F sheath is adequate for all ductal sizes; and the adjustable length of the loop accommodated all types of patent ductus arteriosus. Clinical trials on a larger number of patients are warranted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter occlusion of the patent ductus arteriosus with Cook detachable coils.

OBJECTIVE To report initial experience with a new occlusion device for native and residual patent ductus arteriosus. DESIGN Descriptive study of consecutive non-randomised patients undergoing a new method of patent ductus arteriosus closure with detachable coils. SETTING Tertiary centres for paediatric cardiology. PATIENTS 71 consecutive patients, aged 1.2-22 years, with a patent ductus a...

متن کامل

[Transcatheter closure of patent ductus arteriosus using the Amplatzer duct occluder: initial results and mid-term follow-up].

INTRODUCTION AND OBJECTIVES Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and mid-term results of the treatment of PDA with the Amplatzer duct occluder. PATIENTS AND METHODS From October 1999 to December 2001, 30 children underwent transcatheter closure of persistent ductus arteriosus at a mean SD age of 5 4....

متن کامل

Transcatheter Closure of Patent Ductus Arteriosus Using the Amplatzer Duct Occluder: Initial Results and Mid-Term Follow-Up

Received 11 March 2002. Accepted for publication 28 May 2002. Introduction and objectives. Transcatheter closure of patent ductus arteriosus is a well-established procedure. The aim of this study was to assess the initial and midterm results of the treatment of PDA with the Amplatzer duct occluder. Patients and methods. From October 1999 to December 2001, 30 children underwent transcatheter clo...

متن کامل

Clinical outcome of transcatheter closure of patent ductus arteriosus in small children weighing 10 kg or less

PURPOSE Transcatheter closure has become an effective therapy in most patients with patent ductus arteriosus (PDA). However, there are difficulties in transcatheter closure of PDA in small children. We reviewed clinical outcomes of transcatheter closure of PDA in children weighing less than 10 kg in a single center. METHODS Between January 2003 and December 2009, 314 patients with PDA underwe...

متن کامل

Does change in serum cholesterol of a population influence coronary heart disease mortality?

[1] Shim D, Fedderly RT, Beekman III RH, Ludomirsky A, Young ML, Schork MA, Lloyd TR. Follow-up of coil occlusion of patent ductus arteriosus. J Am Coll Cardiol 1996; 28. 207-11. [2] Galal O, de Moor M, Fadley F et al. Problems encountered during introduction of Gianturco coils for transcatheter occlusion of the patent arterial duct. Eur Heart J 1997; 18: 625-30. [3] Sommer RJ, Gutierrez A, Lai...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 88 3  شماره 

صفحات  -

تاریخ انتشار 1993