A comparison of different mask holds for positive pressure ventilation in a neonatal manikin.
نویسندگان
چکیده
BACKGROUND Ventilation during neonatal resuscitation is typically initiated with a face mask, but may be ineffective due to leak or obstruction. OBJECTIVE To compare leak using three methods of mask hold. METHODS Medical and nursing staff regularly involved in neonatal resuscitation used the three holds (two-point, two-handed, spider) on a manikin in a random order to apply positive pressure ventilation (PPV) at standard settings each for 1 min while mask leak was recorded. RESULTS Participants (n=53) varied in experience (1-23 years) and hand size. Combined median (IQR) leak was 14 (2-46)% and was not different among the holds. CONCLUSIONS There was no difference in the leak measured using the three different mask holds.
منابع مشابه
A Novel Prototype Neonatal Resuscitator That Controls Tidal Volume and Ventilation Rate: A Comparative Study of Mask Ventilation in a Newborn Manikin
The objective of this randomized controlled manikin trial was to examine tidal volume (VT) delivery and ventilation rate during mask positive pressure ventilation (PPV) with five different devices, including a volume-controlled prototype Next Step™ device for neonatal resuscitation. We hypothesized that VT and rate would be closest to target with the Next Step™. Twenty-five Neonatal Resuscitati...
متن کاملPilot manikin study showed that a supraglottic airway device improved simulated neonatal ventilation in a low‐resource setting
AIM We compared the performance of personnel in a low-resource setting when they used the I-gel cuffless neonatal laryngeal mask or a face mask on a neonatal airway management manikin. METHODS At Mulago Hospital, Uganda, 25 doctors, nurses and midwives involved in neonatal resuscitation were given brief training with the I-gel and face mask. Then, every participant was observed positioning bo...
متن کاملA Comparison between Nasal Intermittent Positive Pressure Ventilation and Nasal Continuous Positive Airway Pressure Ventilation in the Treatment of Neonatal Respiratory Distress Syndrome
Background: Nasal intermittent positive pressure ventilation (NIPPV) is a non-invasive ventilatory mode, which delivers mechanical ventilation via nasal tubes or prongs. The present study was conducted to compare the efficacy of NIPPV and nasal continuous positive airway pressure ventilation (NCPAP) in reducing the need for intubation in preterm infants with respiratory distress syndrome (RDS)....
متن کاملCompressive force applied to a manikin's head during mask ventilation.
OBJECTIVE To investigate the compressive force applied to the head during mask ventilation and determine whether this force increases in response to an attempt to correct the mask leak. METHODS The authors asked 24 participants (consultants, fellows and nurses) to administer positive pressure ventilation to a modified leak-free, term newborn manikin using a self-inflating bag (SIB) and a Neop...
متن کاملComparison of Nasal Non-invasive Ventilation Methods in Preterm Neonates with Respiratory Distress Syndrome
Background: Humidified heated high flow nasal cannula (HHHFNC), nasal continuous positive airway pressure (NCPAP), and nasal intermittent positive pressure ventilation (NIPPV) are three nasal non-invasive ventilation methods. The purpose of this study was to compare these three methods in decreasing intubation and mechanical ventilation rate in preterm neonates with respiratory distress syndrom...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of disease in childhood. Fetal and neonatal edition
دوره 99 2 شماره
صفحات -
تاریخ انتشار 2014