Pulpal Temperature Increase with High-speed Handpiece, Er:yag Laser and Ultrasound Tips

نویسندگان

  • Fernanda Brandão Mollica
  • Fernanda Pelogia Camargo
  • Sandra Costa Zamboni
  • Sarina Maciel Braga Pereira
  • Symone Cristina Teixeira
  • Lafayette Nogueira
چکیده

The aim of this study was to compare intrapulpal temperature increase produced by high-speed handpiece, Er:YAG laser and CVDentus ultrasound tips during cavity preparation. Thirty bovine mandibular incisors with an enamel/dentin thickness of 4 mm at buccal surface had their roots amputated and were allocated to the following groups (n=10): Group I- high-speed handpiece; Group II- noncontact Er:YAG laser (250 mJ/4 Hz); and Group III- CVDentus ultrasouns tips. All devices were used with water cooling. Class V cavities were prepared to a depth of 3.5 mm, measured with a periodontal probe. A type T thermocouple was placed inside the pulp chamber to determine the temperature increase (degrees C), which was recorded by a data acquisition system ADS 2000 IP (Lynx Technology) linked to a notebook computer. Data were analyzed statistically by one-way ANOVA and Tukey's test (p=0.05). The mean temperature rises were: 1.10 degrees C (+/-0.56) for Group I, 0.84 degrees C (+/-0.55) for Group II, and 3.00 degrees C (+/- 1.34) for Group III. There were no statistically significant differences (p>0.05) between Groups I and II, but both of them differed significantly from Group III (p<0.05). In conclusion, the use of Er:YAG laser and high-speed handpiece for cavity preparation resulted in similar temperature increase. Although ultrasound tips generated significantly higher intrapulpal temperature increase, it remained below the critical value of 5.5 degrees C and may be considered safe for use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microleakage of cervical cavities prepared by an Er:YAG laser or a high-speed handpiece, after restoration using resin composite

Objectives: The purpose of this in vitro study was to evaluate the microleakage of cervical cavities prepared by Er:YAG laser or high-speed hand piece and bur. Methods: This in vitro experimental study was performed on 40 sound permanent third molar teeth randomly assigned into two equal groups (n=20). In the first group, high-speed hand piece and bur and in the second group Er:YAG la...

متن کامل

Comparison of Er:yag and Er:ysgg Laser Ablation of Dental Hard Tissues

To compare ablation quality of Er:YAG and Er:YSGG laser the surface quality, crater shape, mass loss, and temperature development were determined using the same fibre transmission system and handpiece. Similar crater depths for both lasers but greater diameters for the Er:YAG laser were measured. Also mass loss per pulse of the Er:YAG laser exceeds that of the Er:YSGG laser. Temperature develop...

متن کامل

Micro-CT evaluation of cavities prepared with with different Er:YAG handpieces.

AIM The aim of the study was to compare several cavity shapes after application using different handpieces and tips of Er:YAG laser. MATERIALS AND METHODS Firstly, this in vitro investigation was performed on two upper molars. Their crowns were cut horizontally underneath the occlusal fissures in order to obtain a flat dentin surface. Afterwards, minimal cavities were prepared by using an Er:...

متن کامل

Effect of ER:YAG and diode laser irradiation on the root surface: morphological and thermal analysis.

BACKGROUND The aim of the present study was to compare the effects of Er:YAG and diode laser treatments of the root surface on intrapulpal temperature after scaling and root planing with hand instruments. METHODS Fifteen extracted single-rooted teeth were scaled and root planed with hand instruments. The teeth were divided into 3 groups of 5 each and irradiated on their buccal and lingual sur...

متن کامل

Shear bond strength and SEM evaluation of composite bonded to Er:YAG laser-prepared dentin and enamel.

OBJECTIVES The purpose of this study was to evaluate dentin and enamel bond strength to resin composite following high-speed rotary or Er:YAG laser preparation using a total etch adhesive system. The microstructure of resin-tooth interfaces was also investigated. METHODS Human dentin and enamel specimens were prepared with a high-speed handpiece (KaVo) or Er:YAG laser (DELight) at manufacture...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2008