Thickness Measured Using Computed Tomography and Its Effect on Tip Surgery

نویسندگان

  • Gye Song Cho
  • Jeoung Hyun Kim
  • Nam-Kyung Yeo
  • Soo Hyun Kim
  • Yong Ju Jang
چکیده

Objective. Skin thickness can be a major factor affecting rhinoplasty outcomes. However, few studies have examined the impact of nasal skin thickness on rhinoplasty aesthetic results. The aim of this study is to determine the effect of nasal skin thickness on the tip surgery outcome objectively. Study Design. Case series with chart review. Setting. Academic tertiary care medical center. Subjects and Methods. The study involved 77 patients who were evaluated using preoperative computed tomography scans and underwent rhinoplasty including tip surgery. Surgical outcomes were classified as excellent, good, or poor. Nasal skin thickness was measured at nasion, rhinion, nasal tip, and columella using computed tomography scans and was analyzed according to surgical outcomes. Results. The mean nasal skin thickness was 3.3 mm for nasion, 2.4 mm for rhinion, 2.9 mm for nasal tip, and 2.3 mm for columella. Postoperative outcomes were classified as excellent in 45, good in 17, and poor in 15 patients. The excellent outcome group had the thinnest nasal tip and columella nasal skin (2.8 mm and 2.2 mm), whereas the poor outcome group had the thickest skin in these regions (3.4 mm and 2.6 mm) (P < .0001 and P = 0.01, respectively). Conclusion. Nasal skin is thickest over the nasofrontal angle, thins over the rhinion, is thick again in the nasal tip, and thins out over the columella. Thick skin at the nasal tip and columella was associated with poor surgical outcomes. Regional skin thickness appears to be an important prognostic factor for tip surgery success.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Slice Thickness on the Accuracy of Linear Measurements Made on Cone Beam Computed Tomography Images (InVitro

Objective: Cone beam computed tomography (CBCT) is applied for the imaging of the maxillofacial and dental structures, particularly for surgical treatments and dental implants. The aim of this study was to assess the effect of slice thickness on the accuracy of CBCT linear measurements. Methods: In this diagnostic accuracy study, forty-two titanium pins with the same dimensions were inserted...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

The Prevalence of Unanticipated Hamate Hook Abnormalities in Computed Tomography Scans: A Retrospective Study

 Background:It is possible that some hamate hook fractures are not diagnosed or treated, thereby affecting the study of their natural history. Study of the prevalence of incidental hamate hook fractures, nonunions, and other abnormalities on computed tomography (CT) ordered for another reason could document a subset of undiagnosed and untreated hamate hook fractures which might change our under...

متن کامل

Effect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations

Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...

متن کامل

Measuring the thickness of buccal cortical bone of maxillary premolar teeth by cone beam computed tomography technique

Background and Aims: Immediate implant placement following tooth extraction is a treatment with many advantages. Alveolar bone preservation after immediate implant, need minimum of 2 mm thickness in buccal bone plate. The aim of this study was to evaluate the thickness of buccal cortical bone of maxillary premolars by Cone Beam Computational Tomography (CBCT) technique. Materials and Methods: ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011