Objective measurement of the off-axis longitudinal chromatic aberration in the human eye

نویسندگان

  • M. C. Rynders
  • R. Navarro
  • M. A. Losada
چکیده

Longitudinal chromatic aberration (LCA) of the human eye has been studied repeatedly, but only at the fovea. Poor visual acuity prevents its subjective determination beyond a few degrees eccentricity. Consequently, we have used an objective approach, similar to that of Charman and Jennings [(1976). Vision Research 16, 999-1005], to measure ocular LCA across the visual field. To determine the validity of our double-pass approach, a direct comparison between objective and subjective results was established where possible, namely at the fovea and parafoveally (2.5 deg). In both cases we focused a monochromatic point source at four different wavelengths (458, 501.8, 543.5 and 632.8 nm). At the fovea, for a 3 mm pupil, we found a close match between subjective and objective results. However, as the subjective task became harder (off-axis or larger pupils), subjective results tended to yield slightly more myopic eyes than the results for objective refraction. In all cases, the offset was virtually independent of the wavelength used. Therefore, we have not found evidence of any biased estimates of the LCA, as determined objectively. Our foveal results show reasonable agreement with previous findings, except for slightly smaller amounts of LCA. Starting at the fovea, LCA tends to gradually increase with eccentricity, up to 40 deg, although such an increase is small, just approaching statistical significance. Computation of the LCA using a model eye predicts a slightly smaller increase with eccentricity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peripheral aberrations in the human eye for different wavelengths: off-axis chromatic aberration

The interest in the eye’s off-axis aberrations has increased strongly. On-axis the conversion of the aberration magnitude between different wavelengths is well known. We verified if this compensation is correct also for off-axis measurements by building a wavelength tunable peripheral Hartmann–Shack sensor and measuring 11 subjects out to 30° in the horizontal visual field. At the fovea, an ave...

متن کامل

Construction of special eye models for investigation of chromatic and higher-order aberrations of eyes.

An achromatic element eliminating only longitudinal chromatic aberration (LCA) while maintaining transverse chromatic aberration (TCA) is established for the eye model, which involves the angle formed by the visual and optical axis. To investigate the impacts of higher-order aberrations on vision, the actual data of higher-order aberrations of human eyes with three typical levels are introduced...

متن کامل

Study on chromatic aberration in a population of Chinese myopic eyes by means of optical design

Two kinds of individual eye models, involving and without involving the angle between visual axis and optical axis, are established by means of optical design. We use them to study the properties of the transverse chromatic aberration (TCA) and longitudinal chromatic aberration (LCA) over the visible spectrum. Then the effects of the LCA and TCA on the visual quality of human eyes are evaluated...

متن کامل

Achromatic doublet intraocular lens for full aberration correction.

A doublet intraocular lens optimized for both chromatic and monochromatic aberration correction in pseudophakic eyes is presented. Ray-tracing techniques were applied to design the lens in white light within a chromatic eye model. Combinations of two materials, already commonly used in intraocular lenses, as acrylic and silicone, were used. Iterative optimization algorithms were employed to cor...

متن کامل

Longitudinal chromatic aberration of the human eye in the visible and near infrared from wavefront sensing, double-pass and psychophysics.

Longitudinal Chromatic Aberration (LCA) influences the optical quality of the eye. However, the reported LCA varies across studies, likely associated to differences in the measurement techniques. We present LCA measured in subjects using wavefront sensing, double-pass retinal images, and psychophysical methods with a custom-developed polychromatic Adaptive Optics system in a wide spectral range...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 38  شماره 

صفحات  -

تاریخ انتشار 1998