Matching target dose to target organ

نویسندگان

  • Desmond I. Bannon
  • Marc A. Williams
  • Donald Smith
  • Mir Ahamed Hossain
چکیده

In vitro assays have become a mainstay of modern approaches to toxicology with the promise of replacing or reducing the number of in vivo tests required to establish benchmark doses, as well as increasing mechanistic understanding. However, matching target dose to target organ is an often overlooked aspect of in vitro assays, and the calibration of in vitro exposure against in vivo benchmark doses is often ignored, inadvertently or otherwise.  An example of this was recently published in Environmental Health Perspectives by Wagner et al (2016), where neural stems cells were used to model the molecular toxicity of lead.  On closer examination of the in vitro work, the doses used in media reflected in vivo lead doses that would be at the highest end of lead toxicity, perhaps even lethal.  Here we discuss the doses used and suggest more realistic doses for future work with stem cells or other neuronal cell lines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Organ Specific peripheral dose for Gamma knife 4C based on Monte Carlo

Introduction: Stereotactic Gamma Knife radiosurgery has been widely used for treating brain tumors. The scattered radiation outside of treatment field (peripheral dose) can induce the secondary cancer to specific organ. This paper investigated the absorbed dose to eyes, thyroid, heart, lung, breast and colon using a Monte Carlo technique for Mird phantom. We also study the ef...

متن کامل

Estimation of Photon Specific Absorbed Fractions in Digimouse Voxel Phantom using Monte Carlo Simulation Code FLUKA

Background: Most preclinical studies are carried out on mice. For internal dose assessment of a mouse, specific absorbed fraction (SAF) values play an important role. In most studies, SAF values are estimated using older standard human organ compositions and values for limited source target pairs.Objective: SAF values for monoenergetic photons of energies 15, 50, 100, 500, 1000 and 4000 keV...

متن کامل

Evaluation of the effect of dental filling material on IMRT treatment planning in patient with nasopharyngeal cancer

Introduction: Presence of dental filling material (DFM) such as amalgam in treatment patient with nasopharyngeal cancer (NPC) is common. Streaking artifact Arising from this high density material in computed tomography (scan), may lead to perturbation in dose calculation and dose delivery. Widespread performance of intensity-modulated radiotherapy (IMRT) for NPC using anterior...

متن کامل

Evaluation of Electron Specific Absorbed Fractions in Organs of Digimouse Voxel Phantom Using Monte Carlo Simulation Code FLUKA

Background: For preclinical evaluations of radiopharmaceuticals, most studies are carried out on mice. Values of electron specific absorbed fractions (SAF) have had vital role in the assessment of absorbed dose. In past studies, electron specific absorbed fractions were given for limited source target pairs using older reports of human organ compositions.Objective: Electron specific absorbed fr...

متن کامل

Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching

Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...

متن کامل

Calculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP

Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016