An altitude and distance correction to the source fluence distribution of TGFs

نویسندگان

  • R S Nisi
  • N Østgaard
  • T Gjesteland
  • A B Collier
چکیده

The source fluence distribution of terrestrial gamma ray flashes (TGFs) has been extensively discussed in recent years, but few have considered how the TGF fluence distribution at the source, as estimated from satellite measurements, depends on the distance from satellite foot point and assumed production altitude. As the absorption of the TGF photons increases significantly with lower source altitude and larger distance between the source and the observing satellite, these might be important factors. We have addressed the issue by using the tropopause pressure distribution as an approximation of the TGF production altitude distribution and World Wide Lightning Location Network spheric measurements to determine the distance. The study is made possible by the increased number of Ramaty High Energy Solar Spectroscopic Imager (RHESSI) TGFs found in the second catalog of the RHESSI data. One find is that the TGF/lightning ratio for the tropics probably has an annual variability due to an annual variability in the Dobson-Brewer circulation. The main result is an indication that the altitude distribution and distance should be considered when investigating the source fluence distribution of TGFs, as this leads to a softening of the inferred distribution of source brightness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectral dependence of terrestrial gamma-ray flashes on source distance

[1] We use lightning sferics from theWorldWide Lightning Location Network to identify storms near 362 Terrestrial Gamma-ray Flashes (TGFs). The combined spectrum of TGFs with storms within 300 km of the sub-satellite point is much harder than the spectrum of TGFs with more distant storms. When these data are compared with simulations of vertically oriented relativistic runaway breakdown, it is ...

متن کامل

Quantification the dosimetric parameters of asymmetric physical wedged-6MV photon beam

Introduction: Physical wedge as a useful tool has been utilized in radiotherapy to modify photon beam shape and intensity such that it distributes dose uniformly in tumor site and reduces hot points. Since during Linac commissioning dosimetric parameters like output factors and lateral dose profiles are measured only for symmetric open and wedged fields, so calculation the par...

متن کامل

Estimation of the fluence of high‐energy electron bursts produced by thunderclouds and the resulting radiation doses received in aircraft

[1] Using recent X‐ray and gamma‐ray observations of terrestrial gamma‐ray flashes (TGFs) from spacecraft and of natural and rocket‐triggered lightning from the ground, along with detailed models of energetic particle transport, we calculate the fluence (integrated flux) of high‐energy (million electronvolt) electrons, X rays, and gamma rays likely to be produced inside or near thunderclouds in...

متن کامل

Investigation of the Relationship between Altitude and Aspect with Plant Diversity: A Case Study from Nawa Mountain Ecosystem in Zagros, Iran

Mountain ranges cover around one-half of Iran, and Zagros ecosystem is considered as one of an important biological site in Iran. Physiographic factors such as altitude and aspect have an important role in plant species distribution. This study was conducted in the Nawa mountain ecosystem in the western side of Zagros ranges, located in the western zone of Iran in 2016. The experiment aim was t...

متن کامل

FLUENCE MAP OPTIMIZATION IN INTENSITY MODULATED RADIATION THERAPY FOR FUZZY TARGET DOSE

Although many methods exist for intensity modulated radiotherapy (IMRT) fluence map optimization for crisp data, based on clinical practice, some of the involved parameters are fuzzy. In this paper, the best fluence maps for an IMRT procedure were identifed as a solution of an optimization problem with a quadratic objective function, where the prescribed target dose vector was fuzzy. First, a d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 119  شماره 

صفحات  -

تاریخ انتشار 2014