Geometric accuracy of the MR imaging techniques in the presence of motion

نویسندگان

  • Tarraf Torfeh
  • Rabih Hammoud
  • Tarek El Kaissi
  • Maeve McGarry
  • Souha Aouadi
  • Hadi Fayad
  • Noora Al‐Hammadi
چکیده

Magnetic Resonance Imaging (MRI) is increasingly being used for improving tumor delineation and tumor tracking in the presence of respiratory motion. The purpose of this work is to design and build an MR compatible motion platform and to use it for evaluating the geometric accuracy of MR imaging techniques during respiratory motion. The motion platform presented in this work is composed of a mobile base made up of a flat plate and four wheels. The mobile base is attached from one end and through a rigid rod to a synchrony motion table by Accuray® placed at the end of the MRI table and from the other end to an elastic rod. The geometric accuracy was measured by placing a control point-based phantom on top of the mobile base. In-house software module was used to automatically assess the geometric distortion. The blurring artifact was also assessed by measuring the Full Width Half Maximum (FWHM) of each control point. Our results were assessed for 50, 100, and 150 mm radial distances, with a mean geometric distortion during the superior-inferior motion of 0.27, 0.41, and 0.55 mm, respectively. Adding the anterior-posterior motion, the mean geometric distortions increased to 0.4, 0.6, and 0.8 mm. Blurring was observed during motion causing an increase in the FWHM of ≈30%. The platform presented in this work provides a valuable tool for the assessment of the geometric accuracy and blurring artifact for MR during motion. Although the main objective was to test the spatial accuracy of an MR system during motion, the modular aspect of the presented platform enables the use of any commercially available phantom for a full quality control of the MR system during motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Assessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements

Introduction:  Image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  Geometric  Distortion  of  MR  tomograms.  In  this  study,  the...

متن کامل

Imaging of parathyroid lesions with radionuclides - Is it worth doing?

Parathyroid adenomas, or hyperplasia may be present in patients with hypercalcemia. Treatment Is by surgical excision, but about 10% of the lesions may be In ectopic locations. Pre-operative localization of the lesions with non-lvasive imaging, using radionuclides, ultrasound, CT, or MR], may simplify surgery, and reduce patient morbidity. However, the reports of the accuracy of the curre...

متن کامل

Dynamic Contrast Magnetic Resonance Imaging (DCE-MRI) and Diffusion Weighted MR Imaging (DWI) for Differentiation between Benign and Malignant Salivary Gland Tumors

Background: Salivary gland tumors form nearly 3% of head and neck tumors. Due to their large histological variety and vicinity to facial nerves, pre-operative diagnosis and differentiation of benign and malignant parotid tumors are a major challenge for radiologists. Objective: The majority of these tumors are benign; however, sometimes they tend to transform into a malignant form. Functional M...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2018