Comparison of 2 root surface area measurement methods: 3-dimensional laser scanning and cone-beam computed tomography

نویسندگان

  • Jintana Tasanapanont
  • Janya Apisariyakul
  • Tanapan Wattanachai
  • Patiyut Sriwilas
  • Marit Midtbø
  • Dhirawat Jotikasthira
چکیده

PURPOSE The aim of this study was to compare the use of 3-dimensional (3D) laser scanning and cone-beam computed tomography (CBCT) as methods of root surface measurement. MATERIALS AND METHODS Thirty teeth (15 maxillary first premolars and 15 mandibular first premolars) from 8 patients who required extractions for orthodontic treatment were selected. Before extraction, pre-treatment CBCT images of all the patients were recorded. First, a CBCT image was imported into simulation software (Mimics version 15.01; Materialise, Leuven, Belgium) and the root surface area of each tooth was calculated using 3-Matic (version 7.01, Materialise, Leuven, Belgium). After extraction, all the teeth were scanned and the root surface area of each extracted tooth was calculated. The root surface areas calculated using these 2 measurement methods were analyzed using the paired t-test (P<.05). Correlations between the 2 methods were determined by calculating the Pearson correlation coefficient. The intraclass correlation coefficient (ICC) was used to assess intraobserver reliability. RESULTS The root surface area measurements (230.11±41.97 mm2) obtained using CBCT were slightly greater than those (229.31±42.46 mm2) obtained using 3D laser scanning, but not significantly (P=.425). A high Pearson correlation coefficient was found between the CBCT and the 3D laser scanner measurements. The intraobserver ICC was 1.000 for 3D laser scanning and 0.990 for CBCT. CONCLUSION This study presents a novel CBCT approach for measuring the root surface area; this technique can be used for estimating the root surface area of non-extracted teeth.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of transportation and centering ability using RECIPROC and iRace: A cone-beam computed tomography study

BACKGROUND AND AIM: Root canal treatment, especially in curved and constricted root canals, can be very difficult and time consuming. Several investigations have compared the reciprocating and full sequence motions in terms of shaping ability. The purpose of the present study was to compare the root canal transportation and centering ability of RECIPROC and iRace using cone-beam computed tomogr...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space

Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...

متن کامل

Incidental dentomaxillofacial findings on cone beam computed tomography images of Iranian population

BACKGROUND AND AIM: The present study aimed to assess the nature and prevalence of incidental findings in cone beam computed tomography (CBCT) images of oral and maxillofacial patients. METHODS: In this cross-sectional study, 773 CBCT samples were retrieved from archives of a private oral and maxillofacial radiology center. Any findings that were not related to the reason of CBCT request was re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2017