Testing of Doppler Ultrasound Systems

نویسنده

  • Andrew Walker
چکیده

Blood and tissue velocities are measured and analyzed in cardiac, vascular, and other applications of diagnostic ultrasound. Errors in system performance might give invalid measurements. We developed two moving string test targets and a rotating cylinder phantom (Doppler phantoms) to characterize Doppler ultrasound systems. These phantoms were initially used to measure such variables as sample volume dimensions, location of the sample volume, and the performance of the spectral analysis. Later, specific tests were designed and performed to detect errors in signal processing, causing time delays and inaccurate velocity estimation in all Doppler modes. In cardiac motion pattern even time delays as short as 30 ms may have clinical relevance. These delays can be obtained with echocardiography by using flow and tissue Doppler and M-mode techniques together with external signals (e.g., electrocardiography (ECG) and phonocardiography). If one or more of these signals are asynchronous in relation to the other signals, an incorrect definition of cardiac time intervals may occur. To determine if such time delays in signal processing are a serious problem, we tested four commercial ultrasound systems. We used the Doppler string phantom and the rotating cylinder phantom to obtain test signals. We found time delays of up to 90 ms in one system, whereas delays were mostly short in the other systems. Further, the time delays varied relative to system settings. In two-dimensional (2D) Doppler the delays were closely related to frame rate. To determine the accuracy in velocity calibration, we tested the same four ultrasound systems using the Doppler phantoms to obtain test signals for flow (PW) and tissue (TPW) pulse Doppler and for continuous wave (CW) Doppler. The ultrasound systems were tested with settings and transducers commonly used in cardiac applications. In two systems, the observed errors were mostly close to zero, whereas one system systematically overestimated velocity by an average of 4.6%. The detected errors are mostly negliable in clinical practice but might be significant in certain cases and research applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

I-47: Doppler Ultrasound Diagnosis of Intrauterine Lesions

Background In patients with abnormal uterine bleeding, transvaginal ultrasound (TVS) is the first-line diagnostic approach to exclude endometrial pathology. If a thickened endometrium suggests endometrial pathology, sonohysterography, office hysteroscopy or dilatation and curettage are the second-line tests preferred, depending on availability and on the suspected pathology, to exclude malignan...

متن کامل

Biological Effect of Modern Fetal Ultrasound Techniques on Human Dermal Fibroblast Cells

Background: Diagnostic ultrasound has been used to detect human disease especially fetus abnormalities in recent decades. Although the harmful effects of diagnostic ultrasound on human have not been established so far, several researchers showed it has had bioeffects in cell lines and in experimental animals. Three-dimensional (3D), four-dimensional (4D), and color Doppler sonography are new te...

متن کامل

A new ultrasound sign in the diagnosis of pediatric maxillary sinusitis

      Background: Computed tomography scans (CT scan) and X-rays are used to diagnose paediatric maxillary sinusitis. This study aimed at exploring the diagnostic value of the conventional and colour Doppler ultrasounds and their specific findings in cases of paediatric sinusitis.    Methods: A total of 60 children diagnosed with sinusitis were included in this s...

متن کامل

The Role of Uterine Artery Doppler Ultrasound in the Second Trimester in Predicting Preeclampsia

Background Preeclampsia is a specific pregnancy syndrome. Early diagnosis and proper administration of preeclampsia can lead to improved maternal and neonatal outcome. We aimed to investigate the uterine artery Doppler ultrasound in predicting the preeclampsia in women with a high-risk pregnancy. Materials and Methods This analytic study was conducted on 160 primigravida women with gestational...

متن کامل

Pnm-23: Ultrasound Evaluation of Multiple Pregnancies

Over the past 25 years the rate of twin and higher - order multifetal birth have increased between 1980 and 2005. The twining rate rose from 18.9 to 32.1 per 1000 live birth. Multifetal gestations are at high risk of fetaland complication such as; growth restricted fetal death, LBW and cerebral palasy. Maternal complication are that also increased such as: preeclampsia, diabetes, maternal death...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009