Psychometric Assessment of the Injection Pen Assessment Questionnaire (IPAQ): measuring ease of use and preference with injection pens for human growth hormone
نویسندگان
چکیده
PURPOSE To examine the psychometric properties of the Injection Pen Assessment Questionnaire (IPAQ) including the following: 1) item and scale characteristics (e.g., frequencies, item distributions, and factor structure), 2) reliability, and 3) validity. METHODS Focus groups and one-on-one dyad interviews guided the development of the IPAQ. The IPAQ was subsequently tested in 136 parent-child dyads in a Phase 3, 2-month, open-label, multicenter trial for a new Genotropin(®) disposable pen. Factor analysis was performed to inform the development of a scoring algorithm, and reliability and validity of the IPAQ were evaluated using the data from this two months study. Psychometric analyses were conducted separately for each injection pen. RESULTS Confirmatory factor analysis provides evidence supporting a second order factor solution for four subscales and a total IPAQ score. These factor analysis results support the conceptual framework developed from previous qualitative research in patient dyads using the reusable pen. However, the IPAQ subscales did not consistently meet acceptable internal consistency reliability for some group level comparisons. Cronbach's alphas for the total IPAQ score for both pens were 0.85, exceeding acceptable levels of reliability for group comparisons. CONCLUSIONS The total IPAQ score is a useful measure for evaluating ease of use and preference for injection pens in clinical trials among patient dyads receiving hGH. The psychometric properties of the individual subscales, mainly the lower internal consistency reliability of some of the subscales and the predictive validity findings, do not support the use of subscale scores alone as a primary endpoint.
منابع مشابه
Results from an international multicenter trial evaluating the ease-of-use of and preference for a newly developed disposable injection pen for the treatment of growth hormone deficiency in treatment-naïve children and adults
UNLABELLED Previous research has reported that ease of use of and preference for a delivery device are associated with greater patient compliance - an important factor in achieving optimal therapeutic results. The objective of this study was to assess the ease-of-use of a new disposable pen (GoQuick(®), Pfizer, Inc.) versus the current reusable pen (GENOTROPIN Pen(®), Pfizer, Inc.) to inject a ...
متن کاملEvaluation of the use and handling of three different pen systems considered for in vitro fertilization treatment.
OBJECTIVE The objective of this study was to assess and compare the features of the Bemfola, Gonal-f and Puregon injection pens. METHODS Females who intended to undergo hormonal treatment received the three different pens in a randomized, consecutive sequence. For each of the pens, the potential patients completed an Injection Pen Assessment Questionnaire, as well as a questionnaire comparing...
متن کاملSubcutaneously administered methotrexate for rheumatoid arthritis, by prefilled syringes versus prefilled pens: patient preference and comparison of the self-injection experience
PURPOSE This multicenter, randomized, crossover study compared preference, ease of use, acceptability, satisfaction, and safety of repeated subcutaneous (SC) self-administrations with prefilled pens and prefilled syringes delivering methotrexate (MTX), in patients with rheumatoid arthritis (RA). PATIENTS AND METHODS The study (ClinicalTrials.gov number NCT01793259) enrolled 120 patients requi...
متن کاملA new pen device for injection of recombinant human growth hormone: a convenience, functionality and usability evaluation study
Purpose Adherence to recombinant human growth hormone (r-hGH) is critical to growth and other outcomes in patients with growth disorders, but the requirement for daily injections means that ease of use is an important factor. This study assessed the perceived ease of use and functionality of the prototype of a reusable pen injector (pen device) for r-hGH that incorporates several advanced featu...
متن کاملEase of use of two reusable, half-unit increment dosing insulin pens by adult caregivers of children with type 1 diabetes: a randomized, crossover comparison.
Corresponding Author: Mayme Wong, Ph.D., Eli Lilly and Company, Lilly Corporate Center, Drop Code 2234, Indianapolis, IN 46285; email address [email protected] Insulin pens deliver accurate doses, which are important for children who require low doses and are at risk for hypoglycemia.1 Reusable insulin pens that deliver insulin in half-unit (U) increments include HumaPen® LuxuraTM HD (Eli Li...
متن کامل