The accuracy of noninvasive hemoglobin measurement by multiwavelength pulse oximetry after cardiac surgery.
نویسندگان
چکیده
BACKGROUND In March 2008, a new multiwavelength pulse oximeter, the Radical 7 (Rad7; Masimo Corp., Irvine, CA), was developed that offers noninvasive measurement of hemoglobin concentration. Accuracy has been established in healthy adults and some surgical patients, but not in cardiac surgery intensive care patients, a group at high risk of postoperative bleeding events and anemia in whom early diagnosis could improve management. METHODS In this prospective, observational study conducted in a cardiovascular intensive care unit, we compared hemoglobin concentrations shown by the Rad7 with arterial hemoglobin concentrations determined by an automated hematology analyzer, XE-2100 (Roche, Neuilly sur Seine, France). Two software versions of Rad7 (V 7.3.0.1 [42 points of comparison in 14 patients] and the updated V 7.3.1.1 [61 points of comparison in 27 patients]) were studied during two 1-week periods. Bias, defined as the difference between the 2 methods (Masimo SpHb-XE-2100 laboratory hemoglobin), was calculated. A negative bias indicated that the Masimo underestimated hemoglobin compared with the laboratory analyzer. Correlation between the perfusion index given by Rad7 and the hemoglobin bias was also studied. RESULTS Correlations between Rad7 and XE-2100 were weak for both software versions (R2=0.11 for V 7.3.0.1 and R2=0.27 for V 7.3.1.1). Mean bias was -1.3 g/dL for V 7.3.0.1 and -1.7 g/dL for V 7.3.1.1, with wide 95% prediction intervals for the bias (respectively, -4.6 to 2.1 g/dL and -5.7 to 2.3 g/dL). The absolute hemoglobin bias tended to increase when the perfusion index decreased. For the V 7.3.0.1 software, the average absolute bias was 1.9 g/dL for perfusion index<2 and 0.8 g/dL for perfusion index>2 (P=0.03). For V 7.3.1.1, the mean absolute bias was 2.1 g/dL when the perfusion index was <2, and 1.6 g/dL when the perfusion index was >2 (P=0.26). CONCLUSIONS Our study demonstrates poor correlation between hemoglobin measured noninvasively by multiwavelength pulse oximetry and a laboratory hematology analyzer. The difference was greater when the pulse oximetry perfusion index was low, as may occur in shock, hypothermia, or vasoconstriction patients. The multiwavelength pulse oximetry is not sufficiently accurate for clinical use in a cardiovascular intensive care unit.
منابع مشابه
Effects of cardiopulmonary bypass on the accuracy of non-invasive hemoglobin measurement by pulse co-oximetry
Introduction A non-invasive continuous measurement of hemoglobin (Hb) by pulse co-oximetry (SpHb) using Radical-7 (Masimo Corporation, CA, USA) is a newly developed method of measuring total Hb concentration. Previously, the accuracy of SpHb in clinical settings was reported (1). However, it has been also reported that SpHb has poor correlation with arterial Hb after cardiac surgery (2). Here w...
متن کاملThe Effect of Cardiopulmonary Bypass on the Accuracy of Non-Invasive Hemoglobin Measurement by Pulse Co- Oximetry
Background: A non-invasive continuous measurement of hemoglobin (Hb) by pulse co-oximetry (SpHb) using Radical-7® (Masimo Corporation, CA, USA) is a newly developed method of measuring total Hb concentration. Previously, the accuracy of SpHb in clinical settings was reported (1). However, it has been also reported that SpHb has poor correlation with arterial Hb after cardiac surgery (2). Here w...
متن کاملAccuracy of noninvasive haemoglobin measurement by pulse oximetry depends on the type of infusion fluid
Context Measurement of blood haemoglobin (Hb) concentration by pulse oximetry (SpHb) could be of value to determine when erythrocytes should be transfused during surgery, but the effect of infusion fluids on the results is unclear. Objective To study the effect of crystalloid and colloid fluid on the accuracy (bias) and precision of SpHb to indicate the venous Hb concentration in volunteers. De...
متن کاملThe measurement of dyshemoglobins and total hemoglobin by pulse oximetry.
PURPOSE OF REVIEW Recent advances in pulse oximetry have made it possible to noninvasively measure total hemoglobin, as well as the two most common dyshemoglobins. This review will trace the development and clinical application of multiwavelength pulse oximetry. RECENT FINDINGS Until now, commercially produced pulse oximeters have utilized two wavelengths of light and could measure only the r...
متن کاملAccuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients.
OBJECTIVE To determine whether noninvasive hemoglobin measurement by Pulse CO-Oximetry could provide clinically acceptable absolute and trend accuracy in critically ill patients, compared to other invasive methods of hemoglobin assessment available at bedside and the gold standard, the laboratory analyzer. DESIGN Prospective study. SETTING Surgical intensive care unit of a university teachi...