Utilizing FEM-Software to quantify pre- and post-interventional cardiac reconstruction data based on modelling data sets from surgical ventricular repair therapy (SVRT) and cardiac resynchronisation therapy (CRT)
نویسندگان
چکیده
BACKGROUND Left ventricle (LV) 3D structural data can be easily obtained using standard transesophageal echocardiography (TEE) devices but quantitative pre- and intraoperative volumetry and geometry analysis of the LV is presently not feasible in the cardiac operation room (OR). Finite element method (FEM) modelling is necessary to carry out precise and individual volume analysis and in the future will form the basis for simulation of cardiac interventions. METHOD A Philips/HP Sonos 5500 ultrasound device stores volume data as time-resolved 4D volume data sets. In this prospective study TomTec LV Analysis TEE Software was used for semi-automatic endocardial border detection, reconstruction, and volume-rendering of the clinical 3D echocardiographic data. With the software FemCoGen a quantification of partial volumes and surface directions of the LV was carried out for two patients data sets. One patient underwent surgical ventricular repair therapy (SVR) and the other a cardiac resynchronisation therapy (CRT). RESULTS For both patients a detailed volume and surface direction analysis is provided. Partial volumes as well as normal directions to the LV surface are pre- and post-interventionally compared. CONCLUSION The operation results for both patients are quantified. The quantification shows treatment details for both interventions (e.g. the elimination of the discontinuities for CRT intervention and the segments treated for SVR intervention). The LV quantification is feasible in the cardiac OR and it gives a detailed and immediate quantitative feedback of the quality of the intervention to the medical.
منابع مشابه
Cardiac resynchronisation therapy in heart failure patients with narrow QRS complex: quo vadis?
(CRT) is an established mode of electrical therapy for advanced heart failure that is refractory to optimal drug treatment. CRT has earned its evidence-based credentials through large randomised clinical trials, which have shown significant reductions in morbidity as well as in mortality among patients with a prolonged QRS complex and moderate to severe heart failure. The recently issued guidel...
متن کاملMSCT labelling for pre-operative planning in cardiac resynchronization therapy.
The objective of this paper is twofold: (i) to show how multislice computed tomography (MSCT) data sets bring the information required for cardiac resynchronisation therapy (CRT) planning; (ii) to demonstrate the feasibility of 3D navigation into the veins where left ventricular leads have to be placed. The former has been achieved by exploring and labelling the cardiac structures of concern, t...
متن کاملSurgical placement of left ventricular lead for cardiac resynchronisation therapy after failure of percutaneous attempt
OBJECTIVE Cardiac resynchronisation therapy has been shown to be an effective treatment to improve functional status and prolong survival of patients in advanced chronic heart failure. This study assessed the surgical outcomes of left anterior mini-thoracotomy for the implantation of left ventricular epicardial pacing leads in cardiac resynchronisation therapy. METHODS Our study consisted of ...
متن کاملCARDIOVASCULAR MEDICINE Reverse remodelling of systolic left ventricular contraction pattern by long term cardiac resynchronisation therapy: colour Doppler shows resynchronisation
Objective: To quantify long term effects of cardiac resynchronisation therapy (CRT) by biventricular pacing in patients with heart failure (HF). Methods: Regional changes in left ventricular (LV) contraction patterns effected by CRT in 19 patients with HF (12 with ischaemia; mean (SD) age 66 (9) years) with bundle branch block were examined by colour Doppler tissue velocity imaging (c-TVI). Tim...
متن کاملBalloon Venoplasty of Subclavian Vein and Brachiocephalic Junction to Enable Left Ventricular Lead Placement for Cardiac Resynchronisation Therapy
This report describes the successful implantation of a LV lead using balloon venoplasty to overcome a very tight stenosis of the right subclavian vein / brachiocephalic junction for cardiac resynchronisation therapy (CRT-P) in a patient with a right sided CRT-P system and a failed epicardial LV lead. It is important for device implanters to be familiar with interventional equipments and techniq...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BioMedical Engineering OnLine
دوره 5 شماره
صفحات -
تاریخ انتشار 2006