Measuring key parameters of intense pulsed light (IPL) devices.

نویسندگان

  • Godfrey Town
  • Caerwyn Ash
  • Ewan Eadie
  • Harry Moseley
چکیده

BACKGROUND Unlike medical lasers, intense pulsed light (IPL) devices are largely unregulated and unclassified as to degree of safety hazard. With the exception of most of the USA, the United Kingdom and parts of Europe, the Far East and Australia, the sale of IPLs is generally unrestricted, with the majority being sold into the beauty therapy and spa markets. Standards are only imposed on manufacturers for technical performance data and operating tolerances determined by CE-compliance under electrical safety standards or the EU Medical Device Directive. Currently, there is no requirement for measurement of key IPL performance characteristics. OBJECTIVE To identify the key IPL parameters, emphasize their importance in terms of safe and effective treatment and provide examples of preliminary measurement methods. These measurements can highlight changes in an IPL device's performance, improving patient safety and treatment efficacy. METHODS Five key parameters were identified as having an important role to play in the way light interacts with the skin, and therefore an important role in patient safety and effective treatment. Simple methods were devised to measure the parameters, which include fluence, pulse duration, pulse profile, spectral output and time-resolved spectral output. RESULTS The measurement methods permitted consistent and comparable measurements to be made by two of the authors at working clinic locations on 18 popular IPL devices and allowed assessment of output variations. Results showed discrepancies between the measured IPL device outputs and those values displayed on the system or claimed by the manufacturers. The importance of these discrepancies and their impact is discussed. CONCLUSIONS This study, of 18 popular devices in regular daily use in England and Wales, provides example methods for measuring key IPL device parameters and highlights the need for regular measurement of at least those five key parameters measured in this study. These methods can help service technicians to check performance and eliminate device malfunction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Angioma serpiginosum successfully treated by a single session of intense pulsed light therapy

Angioma serpiginosum (AS) is a nevoid capillary malformation developed congenitally or thereafter. The AS stops growing after puberty and may remain persistent throughout life. The pulsed dye laser (PDL) and KTP are used to treat the AS usually after several sessions. We treated a patient with AS with only one session of intense pulsed light (IPL) therapy. A 40-year-old lady with Fitzpatrick sk...

متن کامل

کاربرد نور شدید طپشی در درمان خال Spilus : گزارش چند بیمار

Background: Intense Pulsed Light (IPL) technology is one of our new measures in treating dermatologic disorders including undesirable skin pigmentation. In contrast with lentigines and freckling of the skin, few reports about nevus spilus treatment using intense pulsed light have been published. The aim of current study was to evaluate efficacy and safety of nevus spilus treatment with an inten...

متن کامل

بررسی اثر منبع نوری پالسی پر قدرت (IPL) بر روند پیری ناشی از صدمه آفتاب (Photoaging

Background: Photo-damaged skin is characterized not only by wrinkles and creases but also by epidermal and dermal atrophy, rough skin texture, irregular pigmentation, talengiectasis , laxity and enlarged pores. There is growing interest in the development of noninvasive methods to treat photo-damaged skin. Intense Pulsed Light (IPL), a non-coherent, broadband, pulsed light source is effective i...

متن کامل

Intense pulsed light (IPL): a review.

BACKGROUND Intense pulsed light (IPL) devices use flashlamps and bandpass filters to emit polychromatic incoherent high-intensity pulsed light of determined wavelength spectrum, fluence, and pulse duration. Similar to lasers, the basic principle of IPL devices is a more or less selective thermal damage of the target. The combination of prescribed wavelengths, fluences, pulse durations, and puls...

متن کامل

Intense pulsed light versus advanced fluorescent technology pulsed light for photodamaged skin: a split-face pilot comparison.

Intense pulsed light (IPL) has been a popular nonablative treatment of photodamage. A prospective, randomized, controlled, single-blinded, split-face pilot study compared the efficacy and safety of 2 multitechnology broadband pulsed light platform devices: an IPL device (Lumenis One, Lumenis Corporation, Santa Clara, CA) and a fluorescent pulsed light with advanced fluorescent technology (AFT, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cosmetic and laser therapy : official publication of the European Society for Laser Dermatology

دوره 9 3  شماره 

صفحات  -

تاریخ انتشار 2007