Fatigue assessment in the field: validation of a hand-held electronic psychomotor vigilance task.

نویسندگان

  • Nicole Lamond
  • Drew Dawson
  • Gregory D Roach
چکیده

INTRODUCTION In recent years, there has been an increasing need for a reliable and practical tool for assessing fatigue-related impairment in the field. This study investigated the sensitivity of one potential tool, a 5-min version of the psychomotor vigilance task (PVT) specifically designed for use on personal digital assistants (PDA), to 28 h of sustained wakefulness. METHODS There were 15 participants who slept in the laboratory overnight then remained awake from 08:00 (Day 1) to 12:00 (Day 2). During every second hour, they completed a 10-min PVT, a sustained attention task that is sensitive to the effects of sleep loss and fatigue, and a 5-min PDA-PVT. RESULTS While performance on both tasks significantly varied as a function of hours of wakefulness, responses on the PDA-PVT were typically slower than on the PVT. When performance scores were standardized, the negative impact of increasing hours of wakefulness on performance on the 5-min PDA-PVT and 10-min PVT did not significantly differ. DISCUSSION The findings suggest that the 5-min PDA-PVT may provide a reasonable substitute for the 10-min PVT, particularly in circumstances where a shorter test is required and/or the standard PVT is not as practical.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SHORT COMMUNICATION Fatigue Assessment in the Field: Validation of a Hand-Held Electronic Psychomotor Vigilance Task

LAMOND N, DAWSON D, ROACH GD. Fatigue assessment in the field: validation of a hand-held electronic psychomotor vigilance task. Aviat Space Environ Med 2005; 76:486–9. Introduction: In recent years, there has been an increasing need for a reliable and practical tool for assessing fatigue-related impairment in the field. This study investigated the sensitivity of one potential tool, a 5-min vers...

متن کامل

Tenth International Conference on Managing Fatigue: Abstract for Review Psychomotor Vigilance Task Evaluation for Touchscreen Devices

The Psychomotor Vigilance Task (PVT) is considered the gold standard fatigue detection device and is used frequently in fatigue research. With the rapid development of new technologies it is essential to develop PVT available on different platforms such as touchscreen devices. The big advantage of such PVT is that it can be implemented on small devices and can be easily used in field studies. T...

متن کامل

Citicoline Improves Human Vigilance and Visual Working Memory: The Role of Neuronal Activation and Oxidative Stress

Introduction: Psychomotor performance task is used to assess the arousal and cognitive functions of the central nervous system. Alternatively, human visual working memory reflects the capability of the individual’s short-term memory. Psycho-mental stimuli are linked to the stimulation of Malondialdehyde (MDA) formations. Citicoline is a nootropic nucleotide agent with a favorable effect on the ...

متن کامل

The Psychomotor Vigilance Test: Sources of State and Trait Variance

Within the context of pilot and air traffic controller selection tests the Psychomotor Vigilance Test (PVT, Dinges & Powell, 1985) was evaluated for its underlying sources of variance. The PVT is a simple visual reaction time task, which is well established as a measure of alertness during sustained operations. It provides scores for mean reaction times and number of lapses. While the PVT has p...

متن کامل

Comparing Accounts of Psychomotor Vigilance Impairment Due to Sleep Loss

The effects of fatigue on cognitive processing are not fully understood. Computational modeling research has led to two distinct accounts of fatigue, and specifically its effects on psychomotor vigilance performance, which are both supported by empirical findings. The first account is based on ACT-R and posits that fatigue increases the probability of microlapses. A biomathmatical model of fati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Aviation, space, and environmental medicine

دوره 76 5  شماره 

صفحات  -

تاریخ انتشار 2005