Preparation of a novel iodide-selective electrode based on iodide-miconazole ion-pair and its application to pharmaceutical analysis.
نویسندگان
چکیده
An iodide-miconazole ion-paired complex was used as a suitable ion-exchanger for the preparation of a plasticized-PVC membrane electrode. Among different solvent mediators tested, dioctylsebacate exhibited the proper response characteristics, including Nernstian slope of the calibration curve, fast response time and good reproducibility of the emf values. The electrode exhibits a Nernstian slope of -59.8 +/- 0.5 mV decade(-1) for I- ion over a concentration range of 1.0 x 10(-5) - 1.0 x 10(-2) M with a limit of detection of 7.0 x 10(-6) M. The electrode displays a good selectivity for I- with respect to a number of inorganic and organic species. It canbe used over a pH range of 2.5 - 8.5. The membrane sensor was successfully applied to the determination of iodide in water samples and blood serum, as well as in pharmaceutical products such as iodoquinol and thyroxin.
منابع مشابه
Iodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex
An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...
متن کاملA Selective Iodide Ion Sensor Electrode Based on Functionalized ZnO Nanotubes
In this research work, ZnO nanotubes were fabricated on a gold coated glass substrate through chemical etching by the aqueous chemical growth method. For the first time a nanostructure-based iodide ion selective electrode was developed. The ZnO nanotubes were functionalized with miconazole ion exchanger and the electromotive force (EMF) was measured by the potentiometric method. The iodide ion ...
متن کاملExtractive Spectrophotometric Determination of Miconazole Nitrate in Pure and Pharmaceutical Preparation
A simple extractive spectrophotometric method has been developed for the estimation of miconazole nitratein both pure and pharmaceutical preparation. The method is based on the formation of ion-pair complex of thedrug with acidic dye bromothymol blue (BTB) in acidic condition, followed by its extraction in organic solvent(chloroform). The absorbance was measured against the corresponding blank....
متن کاملA novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples
A new polyvinyl choloride (PVC) membrane sensor for cerium(III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensorexhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with aNernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7M. It has a fast response time (5 s) and can be used for two month...
متن کاملA novel sensor based on a heterocyclic ionophore for cerium (III) analysis in real samples
A new polyvinyl choloride (PVC) membrane sensor for cerium (III) was prepared based on 4,13-didecyl-1,7,10,16-tetraoxa-4,13-diazacyclooctadecane (kryptofix22DD) as an ionophore. The sensor exhibites a linear concentration range of 1.0×10-6 to 1.0×10-1 M, with a Nernstian slope of 18.0±1.0 mV/decade, and a detection limit of 9.7×10-7 M. It has a fast response time (5 s) and can be used for two m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 21 12 شماره
صفحات -
تاریخ انتشار 2005