Multifocal multiphoton microscopy based on multianode photomultiplier tubes.

نویسندگان

  • Ki Hean Kim
  • Christof Buehler
  • Karsten Bahlmann
  • Timothy Ragan
  • Wei-Chung A Lee
  • Elly Nedivi
  • Erica L Heffer
  • Sergio Fantini
  • Peter T C So
چکیده

Multifocal multiphoton microscopy (MMM) enhances imaging speed by parallelization. It is not well understood why the imaging depth of MMM is significantly shorter than conventional single-focus multiphoton microscopy (SMM). In this report, we show that the need for spatially resolved detectors in MMM results in a system that is more sensitive to the scattering of emission photons with reduced imaging depth. For imaging depths down to twice the scattering mean free path length of emission photons (2xl (s) (em)), the emission point spread function (PSF(em)) is found to consist of a narrow, diffraction limited distribution from ballistic emission photons and a broad, relatively low amplitude distribution from scattered photons. Since the scattered photon distribution is approximately 100 times wider than that of the unscattered photons at 2xl (s) (em), image contrast and depth are degraded without compromising resolution. To overcome the imaging depth limitation of MMM, we present a new design that replaces CCD cameras with multi-anode photomultiplier tubes (MAPMTs) allowing more efficient collection of scattered emission photons. We demonstrate that MAPMT-based MMM has imaging depth comparable to SMM with equivalent sensitivity by imaging tissue phantoms, ex vivo human skin specimens based on endogenous fluorophores, and green fluorescent protein (GFP) expressing neurons in mouse brain slices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reassignment of Scattered Emission Photons in Multifocal Multiphoton Microscopy

Multifocal multiphoton microscopy (MMM) achieves fast imaging by simultaneously scanning multiple foci across different regions of specimen. The use of imaging detectors in MMM, such as CCD or CMOS, results in degradation of image signal-to-noise-ratio (SNR) due to the scattering of emitted photons. SNR can be partly recovered using multianode photomultiplier tubes (MAPMT). In this design, howe...

متن کامل

Non-descanned multifocal multiphoton microscopy with a multianode photomultiplier tube.

Multifocal multiphoton microscopy (MMM) improves imaging speed over a point scanning approach by parallelizing the excitation process. Early versions of MMM relied on imaging detectors to record emission signals from multiple foci simultaneously. For many turbid biological specimens, the scattering of emission photons results in blurred images and degrades the signal-to-noise ratio (SNR). We ha...

متن کامل

Multifocal Multiphoton Microscopy for Neurobiological Imaging

Observing neuronal structures and monitoring changes in synaptic connectivity with respect to time have a significant impact on understanding the basis of structural brain abnormalities and the development of therapeutics for their correction. Today, multiphoton excitation fluorescence microscopy is the method of choice for in vivo neuronal imaging with its inherent 3D resolution, minimal photo...

متن کامل

Scattering suppression and confocal detection in multifocal multiphoton microscopy.

We have developed a new descanned parallel (32-fold) pinhole and photomultiplier detection array for multifocal multiphoton microscopy that effectively reduces the blurring effect originating from scattered fluorescence photons in strongly scattering biological media. With this method, we achieve a fourfold improvement in photon statistics for detecting ballistic photons and an increase in spat...

متن کامل

Characterization of a multianode photomultiplier tube for use with scintillating fibers to detect gamma rays

The performance of a multianode photomultiplier tube (MAPMT) with 64 anodes coupled to scintillating fibers has been examined. Such a detector system can be used in a pairproduction gamma-ray telescope as well as in other applications. The characteristics of these tubes (Hamamatsu R5900-00-M64) are presented including single photoelectron sensitivity, electrical and optical cross-talk, and dark...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 15 18  شماره 

صفحات  -

تاریخ انتشار 2007