Development and validation of RP-HPLC method for estimation of Cefotaxime sodium in marketed formulations.

نویسندگان

  • N Lalitha
  • PN Sanjay Pai
چکیده

A RP-HPLC assay method has been developed and validated for cefotaxime. An isocratic RP-HPLC was developed on a SS Wakosil II- C8 column (250 mm ˜4.6 mm i.d., 5 μm) utilizing a mobile phase of ammonium acetate buffer (pH 6.8) and acetonitrile (85:15 v/v) with UV detection at wavelength 252 nm at the flow rate 0 .8 ml/min. The proposed method was validated for sensitivity, selectivity, linearity, accuracy, precision, ruggedness, robustness and solution stability. The response of the drug was linear in the concentration range of 10-70 μg/ml. Limit of detection and Limit of quantification was found to be 0.3 μg/ml and 0.6 μg/ml respectively. The % recovery ranged within 97-102 %. Method, system, interday and intraday precision was found to be within the limits of acceptance criteria. Method was found to be rugged when analysis was carried out by different analyst. The method was found to be sensitive and efficient with 2216 theoretical plates, 0.1128 mm HETP and tailing factor 1. The method was suitable for the quality control of cefotaxime in injection formulations.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous RP-HPLC and UV Spectroscopic Method Development and Validation for Estimation of Ibandronate Sodium in Bulk and Pharmaceutical Dosage Form

The present study describes a simple, accurate, precise and cost effective UV-Vis Spectroscopic and RP-HPLC method for the estimation of Ibandronate sodium (IBN). The determination of Ibandronate sodium (IBN) was performed by both UV and RP-HPLC method using 215 nm as the determination wavelength. The drug was dissolved in NaOH solution (0.1N NaOH) for estimation in UV and in distilled water fo...

متن کامل

Development and Validation of RP-HPLC-UV Method for Determination of Diclofenac Sodium Residues on Surfaces for Cleaning Validation

In recent years, cleaning validation has achieved a position of increasing in the pharmaceutical industry. It provides assurance to the cleaning procedure that ensures equipment is consistently cleaned from the product, detergent and microbial residues to an acceptable level to avoid cross-contamination and adulteration of drug product with other active ingredients. The aim of this study was to...

متن کامل

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 1  شماره 

صفحات  -

تاریخ انتشار 2009