Clinical Performance of Synthesized Two-dimensional Mammography Combined with Tomosynthesis in a Large Screening Population.

نویسندگان

  • Mireille P Aujero
  • Sara C Gavenonis
  • Ron Benjamin
  • Zugui Zhang
  • Jacqueline S Holt
چکیده

Purpose To compare the clinical performance of synthesized two-dimensional (s2D) mammography combined with digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) alone and FFDM combined with DBT in a large community-based screening population by analyzing recall rate, positive predictive value, and cancer detection rate. Materials and Methods This was a retrospective study approved by the institutional review board and was HIPAA compliant with waiver of informed consent. A total of 78 810 screening mammograms from October 11, 2011, to June 30, 2016, were retrospectively collected. Of these, 32 076 were FFDM, 30 561 were DBT-FFDM, and 16 173 were DBT-s2D mammograms. Diagnostic performance of FFDM, DBT-FFDM, and DBT-s2D mammography was compared. Statistical significance was determined by using the Pearson χ2 test and was expressed as odds ratios and related confidence intervals determined by means of logistic regression analysis with pairwise comparisons. Results Recall rates were significantly lower with DBT-s2D mammography (4.3%, 687 of 16 173) when compared with DBT-FFDM (5.8%, 1785 of 30 561; odds ratio, 0.72; 95% confidence interval: 0.65, 0.78; P < .0001) and when compared with FFDM alone (8.7%, 2799 of 32 076; odds ratio, 0.46; 95% confidence interval: 0.43, 0.51). The cancer detection rate was similar among FFDM alone (5.3 of 1000 screening examinations), DBT-FFDM (6.4 of 1000 screening examinations), and DBT-s2D mammography (6.1 of 1000 screening examinations) with no significant difference (FFDM vs DBT-FFDM, P = .08; FFDM vs DBT-s2D, P = .27). The percentage of invasive cancers detected was significantly higher with DBT-s2D mammography (76.5%) than with DBT-FFDM (61.3%, P = .01), and positive predictive values with DBT-s2D mammography (40.8%) were significantly higher than those with DBT-FFDM (28.5%, P < .0001). Conclusion Screening with DBT-s2D mammography in a large community-based practice improved recall rate and positive predictive values without loss of cancer detection rate when compared with DBT-FFDM and FFDM alone. © RSNA, 2017.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU

Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...

متن کامل

Implementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program.

Purpose To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening. Materials and Methods This was...

متن کامل

Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations.

PURPOSE To determine the effect of implementing a screening tomosynthesis program on real-world clinical performance by quantifying differences between interpretation times for conventional screening mammography and combined tomosynthesis and mammography for multiple participating radiologists with a wide range of experience in a large academic center. MATERIALS AND METHODS In this HIPAA-comp...

متن کامل

Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program.

PURPOSE To assess cancer detection rates, false-positive rates before arbitration, positive predictive values for women recalled after arbitration, and the type of cancers detected with use of digital mammography alone and combined with tomosynthesis in a large prospective screening trial. MATERIALS AND METHODS A prospective, reader- and modality-balanced screening study of participants under...

متن کامل

Comparison of two-dimensional synthesized mammograms versus original digital mammograms alone and in combination with tomosynthesis images.

PURPOSE To assess interpretation performance and radiation dose when two-dimensional synthesized mammography (SM) images versus standard full-field digital mammography (FFDM) images are used alone or in combination with digital breast tomosynthesis images. MATERIALS AND METHODS A fully crossed, mode-balanced multicase (n = 123), multireader (n = 8), retrospective observer performance study wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 283 1  شماره 

صفحات  -

تاریخ انتشار 2017