Detection of Disturbing Loads in Power Systems using Non-Active Power

نویسندگان

  • P. Prabu
  • N. Senthilnathan
چکیده

This paper detects the disturbing loads in distorted and/or unbalanced three phase three wire power system. It is based on the simultaneous measurement of four non-active power quantities, which are found on the IEEE Std.1459-2000 method. It allows, achieving better knowledge of the power system when both harmonic distortion and un-balance are present. The proposed method requires only the fundamental components from the harmonic content of voltage and current. The advantage of this method is, it does not require any spectral analysis of voltage and current. In this paper, usefulness is discussed by means of number of model tests, which were carried out on an effortless test system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of Disturbing Loads in Power Systems using Non-Active Powers

This paper detects the disturbing loads in distorted and/or un-balanced three phase three wire power system. It is based on the simultaneous measurement of four non-active power quantities, which are found on the IEEE Std. 1459-2000 method. It allows, achieving better knowledge of the power system when both harmonic distortion and un-balance are present. The proposed method requires only the fu...

متن کامل

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...

متن کامل

The New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace

The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...

متن کامل

The New Definitions for the Power Terms in Distorted and Unbalanced Conditions and Calculation of these Terms for an Electric Arc Furnace

The rapid increase of non-linear loads in the last three decades has caused electrical quantities such as voltages and currents in 3-phase distribution systems to become distorted waveforms. This paper reviews, explains and discusses some new concepts, definitions and new available theory in the unbalanced and distorted systems. The usefulness of the proposed practical definitions is investigat...

متن کامل

Simultaneous power sharing and protection against faults for DGs in microgrid with different loads

The LVRT (Low Voltage Ride Through) is the main characteristic of every power system in faulty conditions. When fault occurs, it is essential for power system such as microgrid to control the voltage and frequency normally. Naturally in fault status, the unbalanced voltage and current are inevitable, but with the aid of LVRT technique, microgrid can keep stability in main system parameters such...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013