On the use of bolus for pacemaker dose measurement and reduction in radiation therapy

نویسندگان

  • Huagang Yan
  • Fanqing Guo
  • Dengsong Zhu
  • Stefan Stryker
  • Sharron Trumpore
  • Kenneth Roberts
  • Susan Higgins
  • Ravinder Nath
  • Zhe Chen
  • Wu Liu
چکیده

Special attention is required in planning and administering radiation therapy to patients with cardiac implantable electronic devices (CIEDs), such as pacemaker and defibrillator. The range of dose to CIEDs that can induce malfunction is large among CIEDs. Clinically significant defects have been reported at dose as low as 0.15 Gy. Therefore, accurate estimation of dose to CIED and dose reduction are both important even if the dose is expected to be less than the often-used 2-Gy limit. We investigated the use of bolus in in vivo dosimetry for CIEDs. Solid water phantom measurements of out-of-field dose for a 6-MV beam were performed using parallel plate chamber with and without 1- to 2-cm bolus covering the chamber. In vivo dosimetry at skin surface above the CIED was performed with and without bolus covering the CIED for three patients with the CIED <5 cm from the field edge. Chamber measured dose at depth ~0.5-1.5 cm below the skin surface, where the CIED is normally located, was reduced by ~7-48% with bolus. The dose reduction became smaller at deeper depths and with smaller field size. In vivo dosimetry at skin surface also indicated ~20%-60% lower dose when using bolus for the three patients. The dose measured with bolus more accurately reflects the dose to CIED and is less affected by contaminant electrons and linac head scatter. In general, the treatment planning system (TPS) calculation underestimated the dose to CIED, but it predicts the CIED dose more accurately when bolus is used. We recommend the use of 1- to 2-cm bolus to cover the CIED during in vivo CIED dose measurements for more accurate CIED dose estimation. If the CIED is placed <2 cm in depth and its dose is mainly from anterior beams, we recommend using the bolus during the entire course of radiation delivery to reduce the dose to CIED.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

  In radiation therapy with high-energy photon beams (E > 10 MV) neutrons are generated mainly in LINACs head thorough (γ,n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the AAPMTG-34 report, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in the functioning of the pac...

متن کامل

On Presentation of Optimal Treatment Plan in Radiotherapy of Parotid Cancer: A Comparison of Nine Techniques in Three Dimensional Conformal Radiation Therapy

Introduction: Today, radiotherapy combined with surgery in the treatment of parotid tumors widely are used specially for high grade parotid tumors. One of concern and challenge issue of radiotherapy is that the treatment of these tumors with irregular surface due to the presence of external ear and region of different physical electron density (air cavities, dense bone, soft t...

متن کامل

Fabrication and Characterization of Bolus Material Using Propylene Glycol for Radiation Therapy

Introduction: This study aimed to evaluate the efficacy of a synthesized bolus in the reduction of damage to body tissues and the protection of the organ at risk (OAR) in radiotherapy application. Several properties of the synthesized bolus, including density, transmission factor, and effective mass attenuation coefficient, were investigated. Material and ...

متن کامل

The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method

Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...

متن کامل

Electron Beam Dose Distribution in the Presence of Non-Uniform Magnetic Field

Introduction Magnetic fields are capable of altering the trajectory of electron beams andcan be used in radiation therapy.Theaim of this study was to produce regions with dose enhancement and reduction in the medium. Materials and Methods The NdFeB permanent magnets were arranged on the electron applicator in several configurations. Then, after the passage of the electron beams (9 and 15 MeV Va...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2018