Gram-negative bloodstream infections in hematopoietic stem cell transplant patients: the roles of needleless device use, bathing practices, and catheter care.
نویسندگان
چکیده
BACKGROUND Between August 1 and October 30, 1998 (outbreak period), an increased incidence of central venous catheter (CVC)-associated gram-negative bacterial bloodstream infection (GN-BSI) was detected in hematopoietic stem cell transplantation (HSCT) candidates and recipients in an outpatient HSCT unit. The objectives of the present study were to determine strategies for controlling the outbreak and identify risk factors for GN-BSI. METHODS Two case-control studies, an assessment of infection control practices, microbiologic studies, and water quality analysis were conducted. A case was defined as any outpatient with a CVC and a primary GN-BSI during the outbreak period. RESULTS All of the 31 case patients identified had needleless intravenous (IV) access devices. Independent risk factors for CVC-associated GN-BSI were self-administered IV infusion (odds ratio [OR] = 6.2; P = .02), lower frequency of needleless device changes (OR = 15.2; P = .03), and more frequent baths (OR = 1.4; P = .05). Interventions included increased frequency of needleless device change, recommending showers rather than baths, and use of CVC protection during showering/bathing. After these interventions, the CVC-associated GN-BSI rate declined to below the preoutbreak period rate (2.1/1000 vs 0.3/1000 CVC-days; P < .01). CONCLUSIONS This study demonstrated an increased risk of CVC-associated GN-BSIs related to self-IV infusion, bathing habits, and frequency of needleless device change. Infection control practices associated with the use of needleless devices may expose susceptible patients to increased risk for BSI.
منابع مشابه
Bloodstream infection associated with needleless device use and the importance of infection-control practices in the home health care setting.
The influence of infection-control practices on bloodstream infection (BSI) risk was examined in a home health care setting in which three needleless devices were used consecutively. A case-control study and a retrospective cohort study were conducted. Risk factors for BSI included lower education level, younger age, having a central venous catheter (CVC) with multiple ports, or having a tunnel...
متن کاملDetection of catheter-related bloodstream infections by the differential-time-to-positivity method and gram stain-acridine orange leukocyte cytospin test in neutropenic patients after hematopoietic stem cell transplantation.
For febrile neutropenic patients who received hematopoietic stem cell transplantation, the Gram stain-acridine orange leukocyte cytospin (AOLC) test and the differential-time-to-positivity method (DTP) were performed. As a diagnostic tool for catheter-related bloodstream infections in these patients, the Gram stain-AOLC test has a lower sensitivity than does the DTP method but acceptable positi...
متن کاملA fall in bloodstream infections followed a change to 2% chlorhexidine in 70% isopropanol for catheter connection antisepsis: a pediatric single center before/after study on a hemopoietic stem cell transplant ward.
BACKGROUND Some catheter-related bloodstream infections originate from catheter connectors; therefore, improved antisepsis of these might be expected to reduce the incidence of such infections. METHODS In this observational before/after study at a pediatric tertiary referral hospital, inpatients up to 16 years old undergoing hemopoietic stem cell transplants were studied. Catheter connection ...
متن کاملThe Changing Epidemiology of Bloodstream Infections and Resistance in Hematopoietic Stem Cell Transplantation Recipients
OBJECTIVE Patients receiving hematopoietic stem cell transplantation (HSCT) are exposed to highly immunosuppressive conditions and bloodstream infections (BSIs) are one of the most common major complications within this period. Our aim, in this study, was to evaluate the epidemiology of BSIs in these patients retrospectively. MATERIALS AND METHODS The epidemiological properties of 312 patient...
متن کاملIncreased rate of catheter-related bloodstream infection associated with use of a needleless mechanical valve device at a long-term acute care hospital.
OBJECTIVE To determine whether introduction of a needleless mechanical valve device (NMVD) at a long-term acute care hospital was associated with an increased frequency of catheter-related bloodstream infection (BSI). DESIGN For patients with a central venous catheter in place, the catheter-related BSI rate during the 24-month period before introduction of the NMVD, a period in which a needle...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of infection control
دوره 37 4 شماره
صفحات -
تاریخ انتشار 2009