Aging Detection of Glass Disc Insulator by Using Infrared Camera
نویسندگان
چکیده
Suitable diagnostic techniques for outdoor glass insulators are important for ensuring the reliablilty and stability of power system. The possibility of insulator flash-over increases, especially when the insulator is covered by pollution layers or has an internal defect. In this paper, a new technique to detect the pollution level and invisible damage by measuring the surface temperature of glass disc insulators is proposed. A high definition camera had been used to determine the surface temperatures of four glass insulators. The effects ofapplied voltage on the surface temperature and its distribution were studied. The results show the possibility of using the infrarad camera to detect the aging level and invisible damages of the glass insulators.
منابع مشابه
Effects of Disc Insulator Type and Corona Ring on Electric Field and Voltage Distribution over 230-kV Insulator String by Numerical Method
Insulator strings with several material and profiles are very common in overhead transmission lines. However, the electric field and voltage distribution of insulator string is uneven which may easily lead to corona, insulators’ surface deterioration and even flashover. So the calculation of the electric field and voltage distribution along them is a very important factor in the operation time....
متن کاملLeakage Current Based Thermal Modeling of Glass Disc Insulator Surface
The stability of transmission lines relies on the health of the insulators, such as glass string insulators, which may occasionally flashover during an overvoltage. The likelihood of flashover increases notably when the glass insulator is wrapped by a wet contaminant layer. In this paper a study of the surface thermal profile of glass disc insulators insulation had been carried out for both cle...
متن کاملAnalysis of Flashover Voltages of Disc Type Insulator under Artificial Pollution Condition (TECHNICAL NOTE)
Through this paper work we have analyzed the effect of different contaminants on the flashover by creating artificial pollution condition, considering the natural condition where more than one salt as contaminant deposits on the surface of insulator at a time, under the wet condition that cause flow of highly leakage current, that leads to flashover. We choses the mixture of different salts, so...
متن کاملCharacterization of charge distribution on the high voltage glass insulator string
Irregularity in charge distribution of an insulator may lead to accelerated aging and electrical breakdown. However, knowledge of charge distribution on the insulation surface is still insufficient albeit has gained worldwide attention. The insufficiency is particularly on the charge profile along the string insulator under AC excitation. Therefore, charges distributions on the surfaces of glas...
متن کاملEnvironmental Effects on Mechanical Properties of Glass/Epoxy and Fiber Metal Laminates, Part I: Hygrothermal Aging
In this article, the effect of hygrothermal aging on mechanical properties of fiber metal laminates (FMLs) and E-glass/epoxy (GE) composites is investigated. First, FML and GE specimens were built using wet lay-up technique under vacuum pressure. Hygrothermal aging simulation was then carried out on both specimen types in distilled water at a constant temperature of 90 °C for 5 weeks. The resul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2017