Automated Corrected MAR Calculation for Characterisation of AE Signals

نویسنده

  • John MCCRORY
چکیده

Measured Amplitude Ratio (MAR) is a form of modal analysis for the classification of Acoustic Emission (AE) signals. MAR uses a comparison of the amplitudes of the first two primary lamb wave modes, symmetric (S0) and asymmetric (A0), to determine the orientation of the damage mechanisms in relation to the sensor. Previous researchers have demonstrated that some damage mechanisms, such as delamination in composite panels, inherently produce and outof-plane movement and so are expected to generate signals with an MAR value below one. On the contrary, other mechanisms, such as matrix cracking, have been connected to in-plane movements and so generate signals with an MAR value above one. Typically, the technique can consume much of the users time as it involves scrutinising many waveforms individually in order to record the amplitudes of their lamb wave mode constituents. Furthermore, due to the nature of each lamb wave mode to attenuate at different rates, the MAR of a single source might appear to be different depending on source to sensor distance. This problem is amplified in larger structures, where differences in lamb wave mode attention have more distance over which to diverge. An automated MAR calculation method that corrects for the attenuation of each lamb wave mode separately is proposed and discussed. The developed technique successfully differentiated sources of matrix cracking and delamination in a composite panel subjected to buckling. Results were validated post-test using c-scanning, digital image correlation and visual inspection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Method for Automated Estimation of Effective Parameters of Complex Auditory Brainstem Response: Adaptive Processing based on Correntropy Concept

Objectives: Automated Auditory Brainstem Responses (ABR) peak detection is a novel technique to facilitate the measurement of neural synchrony along the auditory pathway through the brainstem. Analyzing the location of the peaks in these signals and the time interval between them may be utilized either for analyzing the hearing process or detecting peripheral and central lesions in the human he...

متن کامل

Automated identification and characterisation of discontinuity sets in outcropping rock masses using 3D terrestrial laser scan survey techniques

It is generally accepted that the identification and characterisation of discontinuities in discontinuous rock masses is one of the most important aspects in rock mass modelling. Traditional manual field survey methods for gathering discontinuity properties are biased, hazardous, difficult and time-consuming. This paper describes a computer approach, based on terrestrial laser scan data, which ...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

Cluster Analysis of Acoustic Emission Signals for Carbon/Epoxy Composite in Four-point Bending Test (RESEARCH NOTE)

Due to the extensive use of composites in various industries and the fact that defects reduce ultimate strength and efficiency during operation, detection of failures in composite parts is very important. The aim of this paper is to use Acoustic Emission (AE) non-destructive method in four-point bending test of carbon/epoxy composite to analyze and examine the failure mechanisms. This method is...

متن کامل

Semi-quantitative segmental perfusion scoring in myocardial perfusion SPECT: visual vs. automated analysis

Introduction: It is recommended that the physician apply at least a semi-quantitative segmental scoring system in myocardial perfusion SPECT.  We aimed to assess the agreement between automated semi-quantitative analysis using QPS (quantitative Perfusion SPECT) software and visual approach for calculation of summed stress  score (SSS), summed rest score (SRS) and summed difference score (SDS). ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014