Optimal Reconstruction Filter Parameters for Multi-Headed Brain SPECT: Dependence on Count Activity

نویسندگان

  • Hong-Gang Liu
  • James M. Mountz
چکیده

Objective: Reconstruction parameters must be optimized to approach the improved spatial resolution that is theoretically possible from modern SPECT imaging devices. One important reconstruction consideration is proper selection of the back-projection filter parameters. The aim of this study was to determine which Butterworth filter optimized image resolution for brain SPECT scans. Methods: Ten normal subjects underwent brain SPECT following an intravenous injection of 15-20 mCi mTc-HMPAO (5 subjects) and 30-35 mCi mrc-HMPAO (5 subjects). Subjects were separated into two groups based on the counts per pixel in the anterior projection image: 5 subjects with low-count images (10.4-13.9 counts/pixel) and 5 subjects with high-count images (18.3-21.5 counts/pixel). All subject projection data were reconstructed at cutoff frequencies (Fe) ranging from 0.15-0.3 Nyquist, with orders ranging from 2-12 at each frequency cutoff. Optimal image selection was determined by blinded subjective assessment by three nuclear medicine faculty capable of evaluating brain SPECT image quality. Results: Results demonstrated that for low-count images, optimum Butterworth filter reconstruction parameters were: Fe = 0.20, order 6. For high-count images, optimum parameters were: Fe = 0.225, order 7. Conclusion: The proper selection of Fe is the most critical parameter for optimization of image reconstruction quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators

Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...

متن کامل

Performance Evaluation of FBP Reconstruction in SPECT Imaging

Introduction:  The  purpose  of  this  study  is  to  define  the  optimal  parameters  for  the  tomographic  reconstruction procedure in a routine single photon emission tomography. The Hoffman brain phantom  is modified to evaluate the reconstruction method. The phantom was imaged in a 3 and 2-dimensional  conformation and the results were compared.   Materials  and  Methods:  The  2D  phant...

متن کامل

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

Determination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging

Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...

متن کامل

Qualitative evaluation of filter function in brain SPECT [Persian]

Introduction: Filtering can greatly affect the quality of clinical images. Determining the best filter and the proper degree of smoothing can help to ensure the most accurate diagnosis. Methods: Forty five patient’s data aquired during brain phantom SPECT studies were reconstructed using filtered back-projection technique. The ramp, Shepp-Logan, Cosine, Hamming, Hanning, Butterworth, Metz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014