Activity classification using the GENEA: optimum sampling frequency and number of axes.
نویسندگان
چکیده
INTRODUCTION The GENEA shows high accuracy for classification of sedentary, household, walking, and running activities when sampling at 80 Hz on three axes. It is not known whether it is possible to decrease this sampling frequency and/or the number of axes without detriment to classification accuracy. The purpose of this study was to compare the classification rate of activities on the basis of data from a single axis, two axes, and three axes, with sampling rates ranging from 5 to 80 Hz. METHODS Sixty participants (age, 49.4 yr (6.5 yr); BMI, 24.6 kg·m (3.4 kg·m)) completed 10-12 semistructured activities in the laboratory and outdoor environment while wearing a GENEA accelerometer on the right wrist. We analyzed data from single axis, dual axes, and three axes at sampling rates of 5, 10, 20, 40, and 80 Hz. Mathematical models based on features extracted from mean, SD, fast Fourier transform, and wavelet decomposition were built, which combined one of the numbers of axes with one of the sampling rates to classify activities into sedentary, household, walking, and running. RESULTS Classification accuracy was high irrespective of the number of axes for data collected at 80 Hz (96.93% ± 0.97%), 40 Hz (97.4% ± 0.73%), 20 Hz (96.86% ± 1.12%), and 10 Hz (97.01% ± 1.01%) but dropped for data collected at 5 Hz (94.98% ± 1.36%). CONCLUSION Sampling frequencies >10 Hz and/or more than one axis of measurement were not associated with greater classification accuracy. Lower sampling rates and measurement of a single axis would result in a lower data load, longer battery life, and higher efficiency of data processing. Further research should investigate whether a lower sampling rate and a single axis affects classification accuracy when considering a wider range of activities.
منابع مشابه
Comparison of Raw Acceleration from the GENEA and ActiGraph™ GT3X+ Activity Monitors
PURPOSE To compare raw acceleration output of the ActiGraph™ GT3X+ and GENEA activity monitors. METHODS A GT3X+ and GENEA were oscillated in an orbital shaker at frequencies ranging from 0.7 to 4.0 Hz (ten 2-min trials/frequency) on a fixed radius of 5.08 cm. Additionally, 10 participants (age = 23.8 ± 5.4 years) wore the GT3X+ and GENEA on the dominant wrist and performed treadmill walking (...
متن کاملPhysical activity classification using the GENEA wrist-worn accelerometer.
INTRODUCTION Most accelerometer-based activity monitors are worn on the waist or lower back for assessment of habitual physical activity. Output is in arbitrary counts that can be classified by activity intensity according to published thresholds. The purpose of this study was to develop methods to classify physical activities into walking, running, household, or sedentary activities based on r...
متن کاملPHENETIC ANALYSIS OF THE IRANIAN SPECIES OF THE BROMUS SECTIONS GENEA, NEOBROMUS AND NEVSKIELLA
A phenetic analysis of the 12 taxa or operational taxonomic units (OTUs) belonging to the three sections; Genea, Neobromus, and Nevskiella of the genus Bromus was performed. Unweighted pair-group method using arithmetic averages (UPGMA) and weighted pair-group method using arithmetic averages (WPGMA) clustering and factoriel method analyses were used to set the taxa apart. Forty-four characters...
متن کاملOptimum Ensemble Classification for Fully Polarimetric SAR Data Using Global-Local Classification Approach
In this paper, a proposed ensemble classification for fully polarimetric synthetic aperture radar (PolSAR) data using a global-local classification approach is presented. In the first step, to perform the global classification, the training feature space is divided into a specified number of clusters. In the next step to carry out the local classification over each of these clusters, which cont...
متن کاملEnergy Efficiency Analyses of Toolpaths in a Pocket Milling Process
This paper presents an approach to analytically determine the most energy efficient toolpath strategy in mechanical machining. This was achieved by evaluating the electrical energy requirement of the NC codes generated for the zag, zigzag, and rectangular contour toolpath strategies. The analytical method was validated by performing pocket milling on AISI 1018 steel with the considered toolpath...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medicine and science in sports and exercise
دوره 44 11 شماره
صفحات -
تاریخ انتشار 2012