Background Rasterstereography is a method for stereophotogrammetric surface measurements of the back based on moiré topography[1]. In contrast to all other optical devices, rasterstereography allows an analysis not only of the back surface but also of the underlying spine. This is possible by the use of a spine model, which was created by Turner-Smith[2,3]. So far rasterstereography only allows static measurements. However, it would be of great value to be able to also evaluate the spine and its segments under dynamic conditions.
منابع مشابه
A Semi-Automatic Algorithm for Estimating Cobb Angle
Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal ...
متن کاملEvaluation of a Novel Spine and Surface Topography System for Dynamic Spinal Curvature Analysis during Gait
INTRODUCTION The assessment of spinal deformities with rasterstereography can enhance the understanding, as well as can reduce the number of x-rays needed. However, to date this technique only allows measurements under static conditions. Since it would be of great value to be able to also analyze the spine in dynamic conditions, the present study evaluated a novel rasterstereographic system. ...
متن کاملA Novel Computer-Aided Method to Evaluate Scoliosis Curvature using Polynomial Math Function
Background: Scoliosis is a health problem that causes a side-to-side curvature in the spine. The curvature may have an “S” or “C” shape. To evaluate scoliosis, the Cobb angle has been commonly used. However, digital image processing allows the Cobb angle to be obtained easily and quickly, several researchers have determined that Cobb angle contains high variations (errors) in the measurements. ...
متن کاملDynamic curvature measurement using fibre-optics
Current methods of measuring spinal curvature are limited. Radiographic analysis is associated with significant radiation exposure and clinic based methods, such as inclinometers and goniometers can only resolve static postures [1]. Laboratory systems, capable of dynamic measures are either constrained by line-of-sight or a clearly defined operating field, which may be affected by the presence ...
متن کاملPropose of a novel method to simulate and optimize a polymer optical fiber daylighting system
Optical fiber day lighting systems help the efficiency of using solar energy in the lighting system in domestic, industrial and agricultural sectors. A lot of work has been done on these systems, but the lack of a reliable simulation method to reduce the tolerance, time and cost is evident. In this regard, in this paper, a novel method based on two powerful Optifiber and Zemax software has bee...