Detection of local lung air content by electrical impedance tomography compared with electron beam CT.
نویسندگان
چکیده
The aim of the study was to validate the ability of electrical impedance tomography (EIT) to detect local changes in air content, resulting from modified ventilator settings, by comparing EIT findings with electron beam computed tomography (EBCT) scans obtained under identical steady-state conditions. The experiments were carried out on six anesthetized supine pigs ventilated with five tidal volumes (VT) at three positive end-expiratory pressure (PEEP) levels. The lung air content changes were determined both by EIT (Goe-MF1 system) and EBCT (Imatron C-150XP scanner) in six regions of interest, located in the ventral, middle, and dorsal areas of each lung, with respect to the reference air content at the lowest VT and PEEP, as a change in either local electrical impedance or lung tissue density. An increase in local air content with VT and PEEP was identified by both methods at all regions studied. A good correlation between the changes in lung air content determined by EIT and EBCT was revealed. Mean correlation coefficients in the ventral, middle, and dorsal regions were 0.81, 0.87, and 0.93, respectively. The study confirms that EIT is a suitable, noninvasive method for detecting regional changes in air content and monitoring local effects of artificial ventilation.
منابع مشابه
Validation of computed tomography-based attenuation correction of deviation between theoretical and actual values for four computed tomography scanners
Objective: In this study, we aimed to validate the accuracy of computed tomography-based attenuation correction (CTAC) using the bilinear scaling method.Methods: The measured attenuation coefficient (μm) was compared to a theoretical attenuation coefficient (μt ) using four different CT scanners and an RMI 467 phantom. The effective energy of the CT beam X-rays was calculated, using the aluminu...
متن کاملA dual modality of cone beam CT and electrical impedance tomography for lung imaging
Electrical impedance tomography (EIT) is a new and emerging tomographic imaging system, which is able to provide high temporal resolution with low spatial resolution. In past few years, the EIT has been extensively studied for lung monitoring. Cone beam CT (CBCT) is an imaging system used in radiation therapy unit. The CBCT suffers from motion artefacts, making treatment planning inaccurate. Th...
متن کاملQuantification of lung collapse during peeptitration by electrical impedance tomography in experimental ards - comparison with quantitative ct analysis
Introduction Tidal recruitment of nonaerated lung is a main cause of ventilator associated lung injury. CT as the gold standard for quantifying lung collapse (CT-collapse) is associated with certain risks for the patient (e.g. radiation exposure or transportation) and cannot be used for repeated assessments. Electrical impedance tomography (EIT) instead is a bed-side non-invasive radiation-free...
متن کاملCorrelation between alveolar ventilation and electrical properties of lung parenchyma.
One key problem in modern medical imaging is linking measured data and actual physiological quantities. In this article we derive such a link between the electrical bioimpedance of lung parenchyma, which can be measured by electrical impedance tomography (EIT), and the magnitude of regional ventilation, a key to understanding lung mechanics and developing novel protective ventilation strategies...
متن کاملEarly detection of intravascular large B-cell lymphoma by 18FDG-PET/CT with diffuse FDG uptake in the lung without respiratory symptoms or chest CT abnormalities
Intravascular large B-cell lymphoma (IVLBCL) is a rare and aggressive subtype of systemic extranodal non-Hodgkin diffuse large B-cell lymphoma (DLBCL). We report a rare case of IVLBCL who showed diffuse 18F-fluorodeoxyglucose (FDG) uptake in the lung in FDG-positron emission tomography/computed tomography (PET/CT) without respiratory symptoms or chest CT abnormalities. Serum biochemical studies...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 93 2 شماره
صفحات -
تاریخ انتشار 2002