Validation of a Stability-Indicating Assay of Amprolium Hydrochloride in Water Soluble Powder Formulation using Hydrophilic Interaction Liquid Chromatography

نویسندگان

  • Mashhour Ghanem
  • Saleh Abu-Lafi
چکیده

Article history: Received on: 06/09/2013 Revised on: 03/10/2013 Accepted on: 15/10/2013 Available online: 31/10/2013 A simple stability-indicating method was developed and validated to determine amprolium hydrochloride (HCl) in water soluble powder formulation. The method is based on zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled with photo diode array detector (PDA). The separation was achieved on ZIC-HILIC column (250 mm  4.6 mm, 5 m) at 25°C temperature. The optimized mobile phase consisted of an isocratic solvent mixture of 200mM Ammonium acetate (NH4AC) solution and acetonitrile (ACN) (25:75; v/v) with pH adjusted to 5.7 by glacial acetic acid. The mobile phase flow was fixed at 0.5 ml/min and the analytes were monitored at 267 nm. The effects of the chromatographic conditions on the peak retention, peak USP tailing factor and column efficiency were systematically optimized. Forced degradation experiments were carried out by exposing amprolium HCl standard and the water soluble powder formulation for thermal, photolytic, oxidative and acid-base hydrolytic stress conditions. The degradation products were well-resolved from the main peak and the excipients thus proving that the method is a reliable and stability-indicating. The method was validated as per ICH and USP guidelines and found to be adequate for the routine quantitative determination of amprolium hydrochloride in commercially available water soluble powder dosage forms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

Validation of a Stability-Indicating Hydrophilic Interaction Liquid Chromatographic Method for the Quantitative Determination of Vitamin K3 (Menadione Sodium Bisulfite) in Injectable Solution Formulation

A simple, specific, accurate, and stability-indicating method was developed and validated for the quantitative determination of menadione sodium bisulfite in the injectable solution formulation. The method is based on zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled with a photodiode array detector. The desired separation was achieved on the ZIC-HILIC column (250 m...

متن کامل

A Simple Stability Indicating Method Development and Validation for the Simultaneous Estimation of Naloxone Hydrochloride and Buprenorphine Hydrochloride in Pharmaceutical Dosage Forms by RP-HPLC

A reverse phase high performance liquid chromatographic (RPHPLC) method has been developed and validated for simultaneous estimation of Naloxone Hydrochloride and Buprenorphine Hydrochloride in pure and marketed formulations. Separation was carried out using column Hypersil ODS C18 (250 mm x 4.6mm x 5μm particle size) in isocratic mode using mobile phase composition pH 6.0 ammonium acetate Buff...

متن کامل

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013