Highly sensitive capillary zone electrophoresis with artificial seawater as the background electrolyte and transient isotachophoresis as the on-line concentration procedure for simultaneous determination of nitrite and nitrate in seawater.

نویسندگان

  • Keiichi Fukushi
  • Yusuke Nakayama
  • Jun-ichi Tsujimoto
چکیده

Transient isotachophoresis-capillary zone electrophoresis with artificial seawater as the background electrolyte (BGE) was improved to further lower the limit of detection (LOD) for determination of nitrite and nitrate in seawater. By lowering the pH of BGE, the difference between effective mobility of nitrite and that of nitrate increased, thereby permitting increased sample volumes to be tolerated and their LOD values to decrease. Artificial seawater with pH adjusted to 3.0 using phosphate buffer was adopted as the BGE. To reverse electroosmotic flow (EOF), a capillary was flushed with 0.1 mM dilauryldimethylammonium bromide for 3 min before the capillary was filled with the BGE. Limits of detection (LODs) for nitrite and nitrate were 2.7 and 3.0 microg/l (as nitrogen), respectively. The LODs were obtained at a signal-to-noise ratio of 3. Values of the relative standard deviation (RSD) of peak area for these ions were 2.0 and 0.75%, respectively, when nitrite concentration was 0.05 mg/l and that of nitrate was 0.5 mg/l. The RSDs of peak height were 4.4 and 2.3%. The RSD values of migration time for these ions were 0.19 and 0.17%. The proposed method was applied to determination of nitrite and nitrate in a proposed certified reference material for nutrients in seawater, MOOS-1, distributed by the National Research Council of Canada. Results agreed with the assigned tolerance interval. This method was also applied to determination of these ions in seawater collected around Osaka Bay. Results nearly agreed with those obtained by a conventional spectrophotometric method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous determination of iodide and iodate in seawater by transient isotachophoresis-capillary zone electrophoresis with artificial seawater as the background electrolyte.

We developed capillary zone electrophoresis with transient isotachophoresis (ITP) as an on-line concentration procedure for simultaneous determination of iodide and iodate in seawater. The effective mobility of iodide was decreased by addition of 20 mM cetyltrimethylammonium chloride to an artificial seawater background electrolyte so that transient ITP functioned for both iodide and iodate. Li...

متن کامل

Sensitive determination of anions in saliva using capillary electrophoresis after transient isotachophoretic preconcentration.

A transient isotachophoresis-capillary electrophoresis (tITP-CE) system for the determination of minor inorganic anions in saliva is described. The complete separation and quantification of bromide, iodide, nitrate, nitrite, and thiocyanate has been achieved with only centrifugation and dilution of the saliva sample. In-line tITP preconcentration conditions, created by introduction of the plugs...

متن کامل

Determination of glycyrrhizin in liqueurs by on-line coupled capillary isotachophoresis with capillary zone electrophoresis.

An on-line coupled capillary isotachophoresis-capillary zone electrophoresis method for the determination of glycyrrhizin in liqueurs is described. The optimised electrolyte system was 5 mM HCl+11 mM epsilon-aminocaproic acid+0.05% hydroxyethylcellulose+30% methanol (leading electrolyte), 5 mM caproic acid+30% methanol (terminating electrolyte) and 20 mM caproic acid+10 mM histidine+0.1% hydrox...

متن کامل

Underway monitoring of nanomolar nitrate plus nitrite and phosphate in oligotrophic seawater

To study nutrient dynamics and cycling in oligotrophic open ocean environments, continuous measurements of nanomolar nitrate, nitrite, and phosphate are valuable. However, such studies are usually impeded by the detection limits of conventional nutrient-sensors and analyzers. Here, we developed a shipboard deployable underway system for simultaneously monitoring nitrate plus nitrite and phospha...

متن کامل

Two-Dimensional Capillary Electrophoresis with On-Line Sample Preparation and Cyclodextrin Separation Environment for Direct Determination of Serotonin in Human Urine.

An advanced two-dimensional capillary electrophoresis method, based on on-line combination of capillary isotachophoresis and capillary zone electrophoresis with cyclodextrin additive in background electrolyte, was developed for effective determination of serotonin in human urine. Hydrodynamically closed separation system and large bore capillaries (300-800 µm) were chosen for the possibility to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. A

دوره 1005 1-2  شماره 

صفحات  -

تاریخ انتشار 2003