Can a clinically useful aortic pressure wave be derived from a radial pressure wave?
نویسندگان
چکیده
BACKGROUND The information contained in arterial pressure waveforms is probably underused by most clinicians who manage critically ill patients. It is not generally known that an aortic pressure wave can be synthesized by applying a generalized transfer function to the radial arterial pressure wave. We validated a commercially available system, SphygmoCo (PWV Medical, Sydney). METHODS Ascending aortic pressure waves were synthesized and comparisons were made between the synthesized aortic waveforms, the measured aortic and radial arterial waveforms. Ascending aortic pressure waves (catheter-tip manometer) and radial artery pressure waves (short fluid-filled catheter) were recorded simultaneously in 12 patients with angina pectoris (age 62-76 years) undergoing cardiac catheterization. Patients were studied at rest, following midazolam, sublingual nitroglycerin and during Valsalva manoeuvres. RESULTS Both midazolam and nitroglycerin lowered mean arterial pressure but nitroglycerin caused a more selective decrease in the measured and synthesized aortic systolic pressures than in the radial artery pressure. The synthesized aortic systolic pressure was less, by 6-8 mm Hg (SD 2-3) and the synthesized aortic diastolic pressure greater, by 4 mm Hg (SD 2). Despite these differences in pulse pressure, the synthesized waveform tracked the measured waveform before and during interventions. CONCLUSIONS By deriving an aortic waveform from the radial pulse, monitoring of left ventricular afterload can improve without more invasive means.
منابع مشابه
Validation of a generalized transfer function to noninvasively derive central blood pressure during exercise.
Exercise brachial blood pressure (BP) predicts mortality, but because of wave reflection, central (ascending aortic) pressure differs from brachial pressure. Exercise central BP may be clinically important, and a noninvasive means to derive it would be useful. The purpose of this study was to test the validity of a noninvasive technique to derive exercise central BP. Ascending aortic pressure w...
متن کاملPressure wave reflection assessed from the peripheral pulse: is a transfer function necessary?
Synthesis of the aortic pressure waveform by application of a transfer function to the radial pulse allows the estimation of aortic systolic blood pressure and aortic augmentation index, an index of pressure wave reflection derived from the early systolic component of the waveform. The accuracy of this approach for determining the aortic augmentation index has been questioned, however, and it m...
متن کاملThe second peak of the radial artery pressure wave represents aortic systolic pressure in hypertensive and elderly patients.
BACKGROUND Simultaneous measurement of ascending aorta and radial artery pressure shows that mean and diastolic pressures (DP) are in close agreement in normotensive adults, while systolic pressures (SP) are not. However, in the aortic pressure wave, a second systolic peak appears with increasing age and increases to represent the SP by age 32 yr, while in the radial artery, a second systolic d...
متن کاملSmall Scale Effect on the Buckling Analysis of a Double-Walled Carbon Nanotube under External Radial Pressure Using Energy Method
In this paper, using energy method, small scale effects on the buckling analysis of a double-walled carbon nanotube (DWCNT) under external radial pressure is studied. The constitutive equations derived for a DWCNT using the nonlocal theory of elasticity which Eringen are presented for the first time. By minimizing the second variation of the total energy for a DWCNT, hence, the value of the non...
متن کاملValidation of the transfer function technique for generating central from peripheral upper limb pressure waveform.
Central aortic pressure waveforms can be calculated from the radial artery pressure waveform using a generalized transfer function to correct for pressure wave distortion in the upper limb. Although validated to standards conventionally applied, reservations are still expressed on use of this process, because of the relatively small number of patients from whom appropriate invasive data were ob...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British journal of anaesthesia
دوره 88 4 شماره
صفحات -
تاریخ انتشار 2002