DOE-Based Stability Indicating RP-HPLC Method for Determination of Lacidipine in Niosomal Gel in Rat: Pharmacokinetic Determination

نویسندگان

  • Mohd Qumbar
  • Syed Sarim Imam
  • Mohd Fazil
  • Asgar Ali
چکیده

Lacidipine (LAC) is a calcium channel blocker used in treatment of hypertension. In this study high performance liquid chromatography method (HPLC) is applied to the determination of LAC in rat plasma. The design of experiment used 3factor 3level Box Behnken Design for optimization of mobile phase condition. The effluent was monitored by UV detector at 240 nm, at a flow rate of 1.0 mL/min using amlodipine as internal standard. A linear calibration curve very well fits our data from 20-1200 ng/mL with limit of detection (LOD) quantitation (LOQ) 1.490 and 4.848 ng mL-1 respectively. The method was found to be linear, precise and accurate. Analytes were stable under various conditions (during freeze-thaw, at room temperature, and under deep freeze conditions). The pharmacokinetic study was performed after application of LAC niosomal transgel in rats and results showed enhance bioavailability by 2.57 fold as compared to oral formulation. DOE-Based Stability Indicating RP-HPLC Method for Determination of Lacidipine in Niosomal Gel in Rat: Pharmacokinetic Determination

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method

This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...

متن کامل

A Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms

Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014