Factors affecting blood glucose monitoring: sources of errors in measurement.

نویسنده

  • Barry H Ginsberg
چکیده

Glucose monitoring has become an integral part of diabetes care but has some limitations in accuracy. Accuracy may be limited due to strip manufacturing variances, strip storage, and aging. They may also be due to limitations on the environment such as temperature or altitude or to patient factors such as improper coding, incorrect hand washing, altered hematocrit, or naturally occurring interfering substances. Finally, exogenous interfering substances may contribute errors to the system evaluation of blood glucose. In this review, I discuss the measurement of error in blood glucose, the sources of error, and their mechanism and potential solutions to improve accuracy in the hands of the patient. I also discuss the clinical measurement of system accuracy and methods of judging the suitability of clinical trials and finally some methods of overcoming the inaccuracies. I have included comments about additional information or education that could be done today by manufacturers in the appropriate sections. Areas that require additional work are discussed in the final section.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive Optical Techniques for determination of blood Glucose levels: A Review Article

This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...

متن کامل

Parameters affecting postprandial blood glucose: effects of blood glucose measurement errors.

BACKGROUND The Diabetes Error Test Model (DETM) has been developed to characterize the clinical relevance of the large and varying margins of error of parameters affecting postprandial blood glucose (BG) levels, which increase the risk for hypo- or hyperglycemia. METHODS The DETM is based on a treatment concept aimed at normoglycemia after meals. The model includes as parameters (a) preprandi...

متن کامل

Clinical implications and economic impact of accuracy differences among commercially available blood glucose monitoring systems.

BACKGROUND Despite accuracy standards, there are performance differences among commercially available blood glucose monitoring (BGM) systems. The objective of this analysis was to assess the potential clinical and economic impact of accuracy differences of various BGM systems using a modeling approach. METHODS We simulated additional risk of hypoglycemia due to blood glucose (BG) measurement ...

متن کامل

EFFECTIVENESS OF INSTRUCT COGNITIVE ERRORS IN THE WAY OF PHILOSOPHY FOR CHILDREN AND ADOLESCENTS, IN COGNITIVE ERRORS, WELL-BEING AND BLOOD SUGAR LEVELS OF CHILDREN AND ADOLESCENTS WITH TYPE I DIABETES

Background: Type 1 diabetes is a chronic disease that children and adolescents do not have the ability to care for themselves, despite having enough information about their self-care (nutrition, insulin, exercise, etc.). Self-care, such as any behavior, can be influenced by the way of thinking, and the philosophy teaching method can be a suitable educational tool for changing thinking. The purp...

متن کامل

A prospective study of blood glucose detection using arterial blood gas analysis and peripheral glucometry after cardiac surgery with cardiopulmonary bypass: accuracy and influences

The objectives of this study were to evaluate the accuracy of blood glucose measurements and to analyze the clinicopathological and experimental factors affecting the accuracy of blood glucose measurement devices. The study enrolled 172 patients who underwent cardiac surgery with cardiopulmonary bypass. Arterial, peripheral, and venous blood samples were collected simultaneously every hour to 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 3 4  شماره 

صفحات  -

تاریخ انتشار 2009