Acceleration and Deceleration Capacity of Fetal Heart Rate in an In-Vivo Sheep Model
نویسندگان
چکیده
BACKGROUND Fetal heart rate (FHR) variability is an indirect index of fetal autonomic nervous system (ANS) integrity. FHR variability analysis in labor fails to detect early hypoxia and acidemia. Phase-rectified signal averaging (PRSA) is a new method of complex biological signals analysis that is more resistant to non-stationarities, signal loss and artifacts. It quantifies the average cardiac acceleration and deceleration (AC/DC) capacity. OBJECTIVE The aims of the study were: (1) to investigate AC/DC in ovine fetuses exposed to acute hypoxic-acidemic insult; (2) to explore the relation between AC/DC and acid-base balance; and (3) to evaluate the influence of FHR decelerations and specific PRSA parameters on AC/DC computation. METHODS Repetitive umbilical cord occlusions (UCOs) were applied in 9 pregnant near-term sheep to obtain three phases of MILD, MODERATE, and SEVERE hypoxic-acidemic insult. Acid-base balance was sampled and fetal ECGs continuously recorded. AC/DC were calculated: (1) for a spectrum of T values (T = 1÷50 beats; the parameter limits the range of oscillations detected by PRSA); (2) on entire series of fetal RR intervals or on "stable" series that excluded FHR decelerations caused by UCOs. RESULTS AC and DC progressively increased with UCOs phases (MILD vs. MODERATE and MODERATE vs. SEVERE, p<0.05 for DC [Formula: see text] = 2-5, and AC [Formula: see text] = 1-3). The time evolution of AC/DC correlated to acid-base balance (0.4<[Formula: see text]<0.9, p<0.05) with the highest [Formula: see text] for [Formula: see text]. PRSA was not independent from FHR decelerations caused by UCOs. CONCLUSIONS This is the first in-vivo evaluation of PRSA on FHR analysis. In the presence of acute hypoxic-acidemia we found increasing values of AC/DC suggesting an activation of ANS. This correlation was strongest on time scale dominated by parasympathetic modulations. We identified the best performing [Formula: see text] parameters ([Formula: see text]), and found that AC/DC computation is not independent from FHR decelerations. These findings establish the basis for future clinical studies.
منابع مشابه
مقایسه نتایج Non-stress test اواخر سه ماهه دوم حاملگی در نوزادان با وزن متناسب و نوزادان کوچک نسبت به سن حاملگی در بیمارستان آرش در سال 81-1380
Background: The purpose of this study was to compare electronic fetal heart rate monitoring (EFM) characteristics between Appropriate for Gestational Age (AGA ) and Small for Gestational Age (SGA) fetuses and to determine whether SGA fetuses have specific abnormalities. Materials and Methods: Among children born from Apr 2002 to Mar 2003 in Arash hospital, we identified 300 singleton infants b...
متن کاملP-184: Investigation of Electronic Fetal Monitoring Application during Labor with Cesarean Section and Apgar Score
Background: Electronic fetal monitoring was used in many hospitals before labor and during delivery . The objective of this study was to investigate whether the use of fetal monitoring had effect on neonatal outcomes and cesarean section rate. Materials and Methods: A prospective study on monitoring neonatal Apgar and kind of delivery data, from deliveries occurring at Shahid Sadughi hospital i...
متن کاملارتباط احساس کاهش حرکت جنین توسط مادر حامله ترم با میزان عوارض جنین در طی زایمان
Introduction: The maternal perception of fetal movements at term has been used as an evaluative test of fetal wellbeing since the last 30 years, but there are different reports about its value. The aim of this study was evaluation of decreased fetal movement and relation to situation of fetus in uterus. It is significant that we understand the relationship between decreased fetal movement and i...
متن کاملDeceleration and acceleration capacities of heart rate associated with heart failure with high discriminating performance
Accurate measurements of autonomic nerve regulation in heart failure (HF) were unresolved. The discriminating performance of deceleration and acceleration capacities of heart rate in HF was evaluated in 130 HF patients and 212 controls. Acceleration capacity and deceleration capacity were independent risk factors for HF in males, evaluated by multiple logistic regression analysis, with odds rat...
متن کاملAcceleration and Deceleration Detection and Baseline Estimation
CTG monitoring of the fetal heart rate and uterine contractions during pregnancy and delivery provide information on the physiological condition of the fetus needed to identify hypoxia. Interpretation, however, requires experience and important patterns might be missed or misinterpreted due to stress, exhaustion or distraction. Interpretation has also been reported subjective with poor reproduc...
متن کامل