The effect of CO(2) laser irradiation on failed implant surfaces.

نویسندگان

  • Jamil Awad Shibli
  • Letícia Helena Theodoro
  • Patrícia Haypek
  • Valdir Gouveia Garcia
  • Elcio Marcantonio
چکیده

The aim of this investigation was to evaluate the cleaning effect of CO(2) on surface topography and composition of failed dental implant surfaces. Ten failed dental implants were retrieved from nine patients (mean age, 46.33 +/- 5.81 years) as a result of early or late failure. The implants were divided into two parts: one side of the implant was irradiated with a CO(2) laser (test side), while the other side did not receive irradiation (control side). The CO(2) laser was operated at 1.2 W in a continuous wave for 40 seconds (40 J energy). The handpiece of the CO(2) laser was kept at a distance of 30 mm from the implant surface, resulting in a spot area of 0.031415 cm (38.20 W/cm; 1559 J/cm) in scanning mode (cervical-apical). One unused dental implant was used as a negative control for both groups. All implant surfaces were examined by scanning electron microscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) for element analysis. SEM showed that the surface of the test sides consisted of different degrees of organic residues, appearing mainly as dark stains similar to those observed on the control sides. None of the test surfaces presented alterations such as crater-like alterations, lava-like layers, or melting compared with the nonirradiated surfaces. Foreign elements such as carbon, oxygen, sodium, calcium, and aluminum were detected on both sides. These results suggest that CO(2) laser irradiation does not modify the implant surface, although the cleaning effect was not satisfactory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of sand-blasted, large grit, acid-etched implants

PURPOSE The present study was performed to evaluate the effect of erbium-doped: yttrium, aluminium and garnet (Er:YAG) laser irradiation on sand-blasted, large grit, acid-etched (SLA) implant surface microstructure according to varying energy levels and application times of the laser. METHODS The implant surface was irradiated by the Er:YAG laser under combined conditions of 100, 140, or 180 ...

متن کامل

The effect of erbium-doped: yttrium, aluminium and garnet laser irradiation on the surface microstructure and roughness of double acid-etched implants

PURPOSE One of the most frequent complications related to dental implants is peri-implantitis, and the characteristics of implant surfaces are closely related to the progression and resolution of inflammation. Therefore, a technical modality that can effectively detoxify the implant surface without modification to the surface is needed. The purpose of this study was to evaluate the effect of er...

متن کامل

Treatment of periimplantitis with an Er: YAG Laser and GBR A case report

Treatment of periimplantitis with an Er: YAG Laser and GBR A case report Dr. M. Rismanchian* - Dr. R. Birang** - Dr. A. Moghareh Abed** *- Assistant Professor of Fixed Prosthodontics Dept. Faculty of Dentistry – Isfahan University of Medical Sciences. **- Assistant Professor of Periodontics Dept. Faculty of Dentistry, Isfahan University of Medical Sciences. Introduction: The increasing use of d...

متن کامل

Evaluation of Diode laser (940 nm) irradiation effect on microleakage in class V composite restoration before and after adhesive application

Introduction: Nowadays, the main focus of dental studies is on adhesive dental materials; since clinical long-term success of bonded restorations depended more on marginal microleakage minimization. So, the aim of this study was Evaluation of Diode laser irradiation effect on microleakage in class V composite restoration before and after adhesive application. Materials and methods: In this in v...

متن کامل

Formation of different microstructures on a polyethersulfone film following XeCl laser irradiation

Laser irradiation parameters, especially the laser fluence and the number of pulses are very important factors affecting microstructures formation and improvement of the surface characteristics in different medical, electronic and the other industrial applications. Information about the fluence domain and the number of pulses for the formation of the structures is very important and determines ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Implant dentistry

دوره 13 4  شماره 

صفحات  -

تاریخ انتشار 2004