A single-reagent manual method for directly determining urea nitrogen in serum.

نویسندگان

  • L B Foster
  • J M Hochholzer
چکیده

A direct method is described, in which a single reagent is used without deproteinization, for measuring blood urea nitrogen (BUN) in serum. The reagent is a mixture of diacetylmonoxime, antipyrine (phenazone), and arsenic pentoxide in acid solution. Lipemia, bilirubin to 25 mg/100 ml, hemoglobin to 1g/100 ml, and protein to 20g/100 ml do not affect the results. Beer’s law is followed at 460 nm for BUN concentrations as great as 100 mg/100 ml. The direct method compares favorably with a manual ureaseBerthelot color method and with the diacetylmonoxime procedure as automated for the Technicon SMA 6/60. The method (CV, 6.7%) can be completed in less than 20 mm. The reagent is stable for at least two months.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Manual and automated methods for urea nitrogen measurement in whole serum.

A simple method is described for directly determining serum urea nitrogen, wtihout deproteinization. The urea in 20 Ml of serum or plasma is reacted with diacetylmonoxime in the presence of thiosemicarbazide and cadmium ion under acid conditions. The absorbance of the resulting rose-purple solution is measured at 540 nm. Results agreed excellently with those obtained by a reference method that ...

متن کامل

Kinetic centrifugal analyzer and manual determination of serum urea nitrogen, with use of o-phthaldialdehyde reagent.

o-Phthaldialdehdye reagent was used in assaying urea with a miniature centrifugal analyzer. Seventeen samples can be assayed kinetically in 2 min at a current cost of less than a penny per test. The reaction is initiated in the instrument upon simultaneous mixing of the o-phthaldialdehyde reagent containing 10 microliter of sample with dilute sulfuric acid/N-(1-naphthyl)ethylenediamine dihydroc...

متن کامل

New reagent for use in determination of blood urea nitrogen, with special reference to manual analysis.

I N THE METHOD for the determination of blood urea imitrogeit described by us in Clinical Chemistry, 5, 617 (1959) a suli uric arsenic pentoxide solution is used for the reaction between diacetvl nionoxime and urea. Since the article was published tile manufacturer of time systeln* has recommended tile use of a ferric-alum-acid reagent developed by P. Paubiollsky and based on proposals by F. Mc...

متن کامل

Four commercial urease reagents and a laboratory-prepared reagent compared for analysis of blood urea nitrogen with the Beckman analyzer.

Three laboratory-prepared urease reagents were compared with a commercial preparation supplied for routine use on the Beckman Blood Urea Nitrogen Analyzer. There were discrepancies in results for urea nitrogen among the four urease reagents when matching serum and the corresponding oxalate/fluoride treated plasma were compared as measured with the Beckman Analyzer and continuous-flow (AutoAnaly...

متن کامل

Automated determination of glucose in serum or plasma by a direct o-toluidine procedure.

A LDOHEXOSES REACT WITH o-toluidine in the presence of glacial acetic acid to produce a green color, which follows Beer’s law over a wide range of concentrations. This reaction is relatively selective for glucose. An improvement in manual procedures involving this reaction (1, 2) was reported by Feteris (3), who determined glucose directly on serum without deproteiization. She also improved the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 17 9  شماره 

صفحات  -

تاریخ انتشار 1971