Initial Experience of Endoscopic Phonosurgery With a Prototype of the Therapeutic Rhinolarynx Electronic Endoscope

نویسندگان

  • Masahiro Kawaida
  • Hiroyuki Fukuda
  • Akihiro Shiotani
  • Naoyuki Kohno
چکیده

We performed endoscopic phonosurgery in a patient with a laryngeal lesion using a prototype of the therapeutic rhino-larynx electronic endoscope connected to a video processor (Asahi Optical Co., Ltd.). This therapeutic electronic endoscope differs from the fiberoptic endoscope, because it contains an instrument channel and a miniature television camera attached to the tip of the endoscope, consisting of a small light-sensitive CCD chip. The dynamic image provided by this system is superior in resolution to that obtained by conventional flexible laryngofiberscopes. Using this therapeutic electronic endoscope and flexible forceps, we succeeded in removing a vocal fold polyp. This endoscope can be passed through the nasal passage into the laryngeal cavity. The therapeutic electronic endoscope is introduced and a clinical case is presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electronic Videoendoscopy of Laryngeal Lesions Using a New Type of Rhinolarynx Endoscope Portion

Patients with laryngeal lesions were observed and the lesions were recorded with an electronic videoendoscope system using the PENTAX EPM-3300 video processor and the PENTAX VNL-1330 endoscope portion. The electronic videoendoscope system differs from the conventional fiberoptic endoscope connected to a video camera in that a small monochrome charge-coupled device (CCD) chip is built in the tip...

متن کامل

Management of Pituitary Adenomas: Mononostril Endoscopic Transsphenoidal Surgery

Introduction: The endoscopic transsphenoidal approach for pituitary adenomas and other sellar lesions is quickly becoming the procedure of choice in their surgical management. The most common approach is binostril three-hand technique which requires a large exposure and subjects both nasal cavities to potential trauma. To reduce nasal morbidity, we employ a mononostril two-hand technique with t...

متن کامل

Magnified Examination of Small Colorectal Polyps Using a Prototype Electronic Endoscope

Magnifying electronic endoscopes are frequently used to evaluate the pit patterns of the colorectal mucosa, but such endoscopes suffer from a number of problems. For example, they tend to have long, hard tips and heavy controller sections. In addition, the magnified endoscopic images obtained are often quite coarse due to the small number of pixels in the charge-coupled device (CCD). As a resul...

متن کامل

Clinical Experience With a New Type of Rhino-Larynx Electronic Endoscope PENTAX VNL-1530

We observed recordings of pictures obtained from patients with diseases of the larynx by using a new type of rhino-larynx electronic endoscope, PENTAXVNL-1530 connected to a video processor, PENTAX EPM-3300 (Asahi Optical Co., Ltd.). The electronic endoscope differs from the fiberoptic endoscope in that it contains a small light-sensitive charge coupled device (CCD) chip that is attached to the...

متن کامل

Three-Dimensional Hand-to-Gland Combat: The Future of Endoscopic Surgery?

Objective To compare two dimensional (2D), three-dimensional (3D) non-high-definition (HD), and 3D HD endoscopic surgical techniques. Methods We describe our initial operative experience with a novel 3D HD endoscopic endonasal approach involving a pituitary adenoma resection, provide a case series, and review the current literature. This is the first case in Europe using the new 3D HD endoscope...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Diagnostic and Therapeutic Endoscopy

دوره 1  شماره 

صفحات  -

تاریخ انتشار 1995