Analysis of light noise sources in a recycled Michelson interferometer with Fabry-Perot arms.
نویسندگان
چکیده
We present a method by which the effect of laser field variations on the signal output of an interferometric gravitational wave detector is rigorously determined. Using the Laser Interferometer Gravitational Wave Observatory (LIGO) optical configuration of a power recycled Michelson interferometer with Fabry-Perot arm cavities as an example, we calculate the excess noise after the input filter cavity (mode cleaner) and the dependence of the detector strain sensitivity on laser frequency and amplitude noise, radio frequency oscillator noise, and scattered-light phase noise. We find that noise on the radio frequency sidebands generally limits the detector's sensitivity.
منابع مشابه
Demonstration of a power-recycled Michelson interferometer with Fabry-Perot arms by frontal modulation.
Large-scale gravitational-wave detectors currently under construction such as the LIGO detectors use multiplemirror resonant optical systems containing several surfaces at which the relative phase of interfering light beams must be controlled. We describe a tabletop experiment that demonstrates a scheme for extracting signals in such an interferometer corresponding to deviations from perfect in...
متن کاملStrawman LIGO II Design: A Quantum Limited Interferometer for LIGO
of design The basic optical configuration is a power-recycled and signal-recycled Michelson interferometer with Fabry-Perot ‘transducers’ in the arms. This requires the addition of a signal recycling mirror to the suspended optics at the output ‘dark’ port, and changes in the RF modulation and control systems. The control system relies on a hierarchy of actuators in the seismic and suspension s...
متن کاملExperimental test of an alignment-sensing scheme for a gravitational-wave interferometer.
An alignment-sensing scheme for all significant angular degrees of freedom of a power-recycled Michelson interferometer with Fabry-Perot cavities in the arms was tested on a tabletop interferometer. The response to misalignment of all degrees of freedom was measured at each sensor, and good agreement was found between measured and theoretical values.
متن کاملShot noise in gravitational-wave detectors with Fabry-Perot arms.
Shot-noise-limited sensitivity is calculated for gravitational-wave interferometers with Fabry-Perot arms, similar to those being installed at the Laser Interferometer Gravitational-Wave Observatory (LIGO) and the Italian-French Laser Interferometer Collaboration (VIRGO) facility. This calculation includes the effect of nonstationary shot noise that is due to phase modulation of the light. The ...
متن کاملThe Comparison of Environmental Effects on Michelson and Fabry-Perot Interferometers Utilized for the Displacement Measurement
The optical structure of general commercial interferometers, e.g., the Michelson interferometers, is based on a non-common optical path. Such interferometers suffer from environmental effects because of the different phase changes induced in different optical paths and consequently the measurement precision will be significantly influenced by tiny variations of the environmental conditions. Fab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2000