Air-insufflated high-definition dacryoendoscopy yields significantly better image quality than conventional dacryoendoscopy

نویسندگان

  • Tsugihisa Sasaki
  • Tsutomu Sounou
  • Hideki Tsuji
  • Kazuhisa Sugiyama
چکیده

PURPOSE To facilitate the analysis of lacrimal conditions, we utilized high-definition dacryoendoscopy (HDD) and undertook observations with a pressure-controlled air-insufflation system. We report the safety and performance of HDD. METHODS In this retrospective, non-randomized clinical trial, 46 patients (14 males and 32 females; age range 39-91 years; mean age ± SD 70.3±12.0 years) who had lacrimal disorders were examined with HDD and conventional dacryoendoscopy (CD). The high-definition dacryoendoscope had 15,000 picture element image fibers and an advanced objective lens. Its outer diameter was 0.9-1.2 mm. Air insufflation was controlled at 0-20 kPa with a digital manometer-based pressure-controlled air-insufflation system to evaluate the quality of the image. The HDD had an air/saline irrigation channel between the outer sheath (outer diameter =1.2 mm) and the metal inner sheath of the endoscope. We used it and the CD in air, saline, and diluted milk saline with and without manual irrigation to quantitatively evaluate the effect of air pressure and saline irrigation on image quality. RESULTS In vivo, the most significant improvement in image quality was demonstrated with air-insufflated (5-15 kPa) HDD, as compared with saline-irrigated HDD and saline-irrigated CD. No emphysema or damage was noted under observation with HDD. In vitro, no significant difference was demonstrated between air-insufflated HDD and saline-irrigated HDD. In vitro, the image quality of air-insufflated HDD was significantly improved as compared with that of saline-irrigated CD. CONCLUSION Pressure-controlled (5-15 kPa) air-insufflated HDD is safe, and yields significantly better image quality than CD and saline-irrigated HDD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution dacryoendoscopy for observation for pediatric lacrimal duct obstruction

Purpose The aim of this study was to describe high-resolution dacryoendoscopy findings for nasolacrimal duct obstruction (NLDO) in three representative pediatric cases with different etiologies. Observations In a case of congenital NLDO, a mucosal membranous obstruction was observed at the distal end of the nasolacrimal duct (NLD), and a slit-shaped opening of the NLD was observed after perfo...

متن کامل

Measurement of Air Gap of 30 to 50 Micron Width by Conventional X-Ray Machine

Detection of very fine defects in the width range of a few microns is very difficult by using conventional radiographic equipment, due to three limiting factorscontrast, definition and image graininess. Variables, such as X-ray energy, scattered radiation, type of film, processing parameters, film density, focal spot size, source to object distance etc, if controlled properly, can lead to radio...

متن کامل

Assessment of the Log-Euclidean Metric Performance in Diffusion Tensor Image Segmentation

Introduction: Appropriate definition of the distance measure between diffusion tensors has a deep impact on Diffusion Tensor Image (DTI) segmentation results. The geodesic metric is the best distance measure since it yields high-quality segmentation results. However, the important problem with the geodesic metric is a high computational cost of the algorithms based on it. The main goal of this ...

متن کامل

Lacrimal surgery: Glorious past, exciting present era and the audacity of hope for a brilliant future.

The evolution of lacrimal disorders and its management amply exemplifies the above stated quote of the 20th century British philosopher Bertrand Russell. Lacrimal surgeries have been a subject of discussion in antiquity with the earliest documented reference being a lacrimal sac incision in the ‘Code of Hammurabi’ in 2250 BC. The past which appears glorious today had once traveled through many ...

متن کامل

High Pass SENSE

Introduction Artificially increasing the sparsity of an image before reconstruction has been used to improve the performance of partially parallel imaging techniques [1, 2]. Similar to the requirement of explicit sensitivity maps, an explicit image support (non-zero regions) definition is also required to take fully advantage of image sparsity in conventional SENSE [3]. However, it is not trivi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017